Outcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease: A Comparison Between Bicuspid and Tricuspid Valves
Journal of the American Heart Association · 2026
DOI: 10.1161/jaha.125.047475 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of the American Heart Association, 2026. Verfasst von Yu Tang und 20 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, West China Hospital Sichuan University Chengdu People's Republic of China. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Bicuspid Aortic Valve Disease, Aortic Valve Stenosis, Aortic Valve. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
The impact of aortic valve morphology on outcomes after transcatheter aortic valve replacement in patients with mixed aortic valve disease, characterized by the coexistence of aortic stenosis and regurgitation, remains poorly defined. This study aimed to compare outcomes of transcatheter aortic valve replacement between bicuspid and tricuspid aortic valve morphologies in patients with mixed aortic valve disease.
Methods
We retrospectively analyzed 282 patients with mixed aortic valve disease who underwent transcatheter aortic valve replacement between January 2019 and June 2024, including 82 with bicuspid aortic valve and 200 with tricuspid aortic valve. Propensity score matching at a 1:1 ratio yielded 82 well‐balanced pairs. The primary end point was all‐cause death, and secondary end points included technical success, paravalvular leak, clinical adverse events, hemodynamic performance, and left ventricular reverse remodeling.
Results
Both groups achieved high technical success rates (97.6% versus 93.9%; P =0.443) with comparable procedural outcomes. Although mild or greater paravalvular leak occurred more frequently in the bicuspid aortic valve group, this difference did not translate into higher 1‐year all‐cause death (3.7% versus 3.7%; P >0.999) or adverse events. Hemodynamic performance and left ventricular remodeling improved significantly in both groups; however, patients with bicuspid aortic valve showed more pronounced increase in left ventricular ejection fraction (median, 6.5% [interquartile range, −2.0% to 15.5%] versus 0.5% [interquartile range, −5.0% to 12.0%]; P =0.023), whereas the degree of reverse remodeling was less evident (median, −7.0 [interquartile range, −17.0 to −3.0] versus −11.0 [interquartile range, −20.0 to −6.0] mm; P =0.045).
Conclusions
In patients with mixed aortic valve disease undergoing transcatheter aortic valve replacement, bicuspid aortic valve morphology was associated with more mild or greater paravalvular leak but similar procedural safety, hemodynamic outcomes, and clinical prognosis compared with tricuspid aortic valve, with distinct left ventricular recovery patterns.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, West China Hospital Sichuan University Chengdu People's Republic of China.
- Cardiac Structure and Function Research Key Laboratory of Sichuan Province, West China Hospital Sichuan University Chengdu People's Republic of China.
- Laboratory of Cardiac Structure and Function, Institute of Cardiovascular Diseases, West China Hospital Sichuan University Chengdu People's Republic of China.
ORCID-Profile: Yu Tang, Yuan Feng, Xue-Chen Qiao, Meng-Yun Yan, Yue Yin, Tian-Yuan Xiong, Yi-Ming Li, Jun-Li Li, Lin Bai, Xin Wei, Yi-Jun Yao, Qiao Li, Yi-Jian Li, Jia-Fu Wei, Yong Peng, Zhen-Gang Zhao, Mao Chen
Zitieren
APA
Tang, Y., Feng, Y., Qiao, X. C., Yan, M. Y., Yin, Y., Li, W. Y., Xiong, T. Y., Li, Y. M., Li, J. L., Bai, L., Wei, X., Ou, Y. X., Zhu, Z. K., Yao, Y. J., Li, Q., Li, Y. J., Chen, F., Wei, J. F., Peng, Y., …, & Chen, M. (2026). Outcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease: A Comparison Between Bicuspid and Tricuspid Valves. Journal of the American Heart Association. https://doi.org/10.1161/jaha.125.047475
Vancouver
Tang Y, Feng Y, Qiao XC, Yan MY, Yin Y, Li WY, et al. Outcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease: A Comparison Between Bicuspid and Tricuspid Valves. Journal of the American Heart Association. 2026. doi:10.1161/jaha.125.047475
BibTeX
@article{Tang2026,
author = {Tang, Yu and Feng, Yuan and Qiao, Xue-Chen and Yan, Meng-Yun and Yin, Yue and Li, Wei-Ya and Xiong, Tian-Yuan and Li, Yi-Ming and Li, Jun-Li and Bai, Lin and Wei, Xin and Ou, Yuan-Wei Xiang and Zhu, Zhong-Kai and Yao, Yi-Jun and Li, Qiao and Li, Yi-Jian and Chen, Fei and Wei, Jia-Fu and Peng, Yong and Zhao, Zhen-Gang and Chen, Mao},
title = {Outcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease: A Comparison Between Bicuspid and Tricuspid Valves},
journal = {Journal of the American Heart Association},
year = {2026},
doi = {10.1161/jaha.125.047475}
}
EUVIMED