EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access

Artificial Intelligence‐Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic Value

Jaehyun Lim iD, Min Sung Lee iD, Jung Ho Suh iD, Sora Kang iD, Hak Seung Lee iD, Jong-Hwan Jang, Jeong Min Son iD, Joon-Myoung Kwon, Yong-Jin Kim, Kyung-Hee Kim iD, Seung-Pyo Lee iD

Journal of the American Heart Association · 05.05.2026 · 15 (9)

DOI: 10.1161/jaha.125.046989 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of the American Heart Association, erschienen am 05.05.2026. Verfasst von Jaehyun Lim und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Seoul National University College of Medicine and Seoul National University Hospital Seoul Republic of Korea. Hauptthemen laut MEDLINE: Artificial Intelligence, Echocardiography, Electrocardiography, Heart Failure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Left ventricular filling pressure is associated with heart failure symptoms and a key prognostic marker and therapeutic target, but a scalable, accessible, and affordable tool for its noninvasive, serial estimation remains lacking. We developed an artificial intelligence (AI) model using a standard 12‐lead ECG to detect increased E/e', a general surrogate of elevated left ventricular filling pressure on echocardiography.

Methods

The AI model was built upon a foundation model trained with >1 million multiethnic ECGs and fine‐tuned through a development cohort of 225 737 ECGs and 115 982 echocardiogram records from 92 775 unique patients across 2 tertiary hospitals. The model performance was assessed in a separate internal test set (n=9278) and an independent external cohort from another tertiary hospital (n=17 926). Prognostic significance of the AI‐ECG output was evaluated in these hospital cohorts, as well as the UK Biobank (n=43 347). Finally, we validated the model output against invasively measured left ventricular filling pressure through cardiac catheterization (n=60).

Results

The AI‐ECG model detected increased E/e' with an area under the curve of 0.868 (95% CI, 0.859–0.877) and 0.850 (95% CI, 0.841–0.858) in the internal and external test cohorts, respectively. The AI‐ECG output value demonstrated a strong correlation with invasively measured left ventricular end‐diastolic pressure (Pearson's r=0.655) and was significantly associated with incident heart failure and mortality.

Conclusions

The AI‐ECG may enable identification of patients with increased left ventricular filling pressure and provide powerful prognostic information. Further prospective studies are warranted to evaluate its clinical utility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceEchocardiographyElectrocardiographyHeart FailureHemodynamicsVentricular Function, LeftAgedFemaleHumansMaleMiddle AgedPredictive Value of TestsPrognosisVentricular Pressure

Stichwörter der Autor:innen

ECGartificial intelligenceleft ventricular filling pressureprognosis

Autor:innen und Institutionen

  • Department of Internal Medicine, Seoul National University College of Medicine and Seoul National University Hospital Seoul Republic of Korea.
  • Digital Healthcare Institute Sejong Hospital Bucheon Republic of Korea.
  • Medical AI Co., Ltd. Seoul Republic of Korea.
  • Biomedical Research Institute, Seoul National University Seoul Republic of Korea.
  • Healthcare AI Research Institute, Seoul National University Hospital Seoul Republic of Korea.
  • Division of Cardiology, Department of Internal Medicine, Incheon Sejong Hospital, Cardiovascular Center Incheon Republic of Korea.

ORCID-Profile: Jaehyun Lim, Min Sung Lee, Jung Ho Suh, Sora Kang, Hak Seung Lee, Jeong Min Son, Kyung-Hee Kim, Seung-Pyo Lee

Zitieren

APA

Lim, J., Lee, M. S., Suh, J. H., Kang, S., Lee, H. S., Jang, J. H., Son, J. M., Kwon, J. M., Kim, Y. J., Kim, K. H., & Lee, S. P. (2026). Artificial Intelligence‐Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic Value. Journal of the American Heart Association, 15(9). https://doi.org/10.1161/jaha.125.046989

Vancouver

Lim J, Lee MS, Suh JH, Kang S, Lee HS, Jang JH, et al. Artificial Intelligence‐Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic Value. Journal of the American Heart Association. 2026;15(9). doi:10.1161/jaha.125.046989

BibTeX
@article{Lim2026,
  author = {Lim, Jaehyun and Lee, Min Sung and Suh, Jung Ho and Kang, Sora and Lee, Hak Seung and Jang, Jong-Hwan and Son, Jeong Min and Kwon, Joon-Myoung and Kim, Yong-Jin and Kim, Kyung-Hee and Lee, Seung-Pyo},
  title = {Artificial Intelligence‐Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic Value},
  journal = {Journal of the American Heart Association},
  year = {2026},
  volume = {15},
  number = {9},
  doi = {10.1161/jaha.125.046989}
}
Kostenlos starten →