Clinical Impact and Lesion Characteristics of Suboptimal Optical Coherence Tomography Stent Deployment in Patients With Acute Myocardial Infarction
Journal of the American Heart Association · 02.06.2026 · 15 (11)
DOI: 10.1161/jaha.125.045609 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Heart Association, erschienen am 02.06.2026. Verfasst von Jiawei Zhao und 22 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology The 2nd Affiliated Hospital of Harbin Medical University Harbin China. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Drug-Eluting Stents, Myocardial Infarction, Percutaneous Coronary Intervention. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Suboptimal stent deployment detected by optical coherence tomography (OCT) correlates with adverse outcomes, yet its long‐term prognosis and associations with lesion characteristics in patients with acute myocardial infarction (MI) receiving drug‐eluting stents remain unclear. This study aimed to investigate the impact of OCT‐defined stent parameters on long‐term outcomes and identify lesion features predictive of suboptimal stent deployment in patients with acute MI.
Methods
Between January 2018 and December 2020, patients with acute MI undergoing successful intervention with drug‐eluting stents and postprocedural OCT imaging at the target lesions were included. The end point was device‐oriented cardiovascular events, a composite of cardiac death, target‐vessel related MI, and target‐lesion revascularization. Suboptimal OCT stent deployment was defined as the presence of ≥1 OCT findings significantly associated with device‐oriented cardiovascular events. In a subgroup with preprocedural OCT imaging for target lesions, lesion morphology was assessed.
Results
Among 881 patients (906 lesions with final OCT imaging), minimum stent area
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology The 2nd Affiliated Hospital of Harbin Medical University Harbin China.
- The Key Laboratory of Myocardial Ischemia Chinese Ministry of Education Harbin China.
- State Key Laboratory of Frigid Zone Cardiovascular Diseases (SKLFZCD) Harbin China.
- International Medical Center, The 2nd Affiliated Hospital of Harbin Medical University Harbin China.
ORCID-Profile: Xianqin Ma, Fuhong Dong, Jiawen Chen, Jinfeng Tan, Huai Yu, Yini Wang, Jingbo Hou, Jiannan Dai, Bo Yu
Zitieren
APA
Zhao, J., Zhao, R., Chen, Y., Cui, L., Ma, X., Lin, T., Dong, F., Chen, J., Tan, J., Wu, T., Sun, Z., Jin, C., Xiu, L., Wang, W., Yu, H., Liu, Y., Wei, G., Li, L., Wang, Y., …, & Yu, B. (2026). Clinical Impact and Lesion Characteristics of Suboptimal Optical Coherence Tomography Stent Deployment in Patients With Acute Myocardial Infarction. Journal of the American Heart Association, 15(11). https://doi.org/10.1161/jaha.125.045609
Vancouver
Zhao J, Zhao R, Chen Y, Cui L, Ma X, Lin T, et al. Clinical Impact and Lesion Characteristics of Suboptimal Optical Coherence Tomography Stent Deployment in Patients With Acute Myocardial Infarction. Journal of the American Heart Association. 2026;15(11). doi:10.1161/jaha.125.045609
BibTeX
@article{Zhao2026,
author = {Zhao, Jiawei and Zhao, Rui and Chen, Yuzhu and Cui, Lina and Ma, Xianqin and Lin, Tong and Dong, Fuhong and Chen, Jiawen and Tan, Jinfeng and Wu, Tianyu and Sun, Zhao and Jin, Chengmei and Xiu, Lili and Wang, Wei and Yu, Huai and Liu, Yanchao and Wei, Guo and Li, Lulu and Wang, Yini and Hou, Jingbo and Fang, Chao and Dai, Jiannan and Yu, Bo},
title = {Clinical Impact and Lesion Characteristics of Suboptimal Optical Coherence Tomography Stent Deployment in Patients With Acute Myocardial Infarction},
journal = {Journal of the American Heart Association},
year = {2026},
volume = {15},
number = {11},
doi = {10.1161/jaha.125.045609}
}
EUVIMED