Klinische Studie in der Zeitschrift Journal of the American Heart Association, 2026. Verfasst von Hui Li und 10 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Cardiovascular Disease, Department of Echocardiography, National Center for Cardiovascular Diseases, Fuwai Hospital Chinese A…. Hauptthemen laut MEDLINE: Artificial Intelligence, Deep Learning, Echocardiography, Transesophageal, Mitral Valve. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transcatheter edge‐to‐edge mitral valve repair is a key therapeutic option for patients with severe symptomatic mitral regurgitation at high surgical risk. This prospective study aimed to develop a novel end‐to‐end deep learning model for preoperative artificial intelligence assessment in transcatheter edge‐to‐edge mitral valve repair (TEERAI‐pre) candidates using multiview, multimodal echocardiography.

Methods

TEERAI‐pre, a video vision transformer–based classification model, predicts morphological suitability for transcatheter edge‐to‐edge mitral valve repair from multiview, multimodal echocardiography. A transformer‐based feature‐level fusion module was designed in TEERAI‐pre to integrate multiview, multimodal features for final prediction. An internal data set of 633 patients (7997 transthoracic echocardiographic videos; 766 pulsed‐wave Doppler images) was split for 5‐fold cross‐validation. An external data set of 150 patients (1735 transthoracic echocardiographic videos; 169 pulsed‐wave Doppler images) across 2 hospitals evaluated generalizability. Reference standards were provided by 2 experienced valvular cardiologists per international guidelines.

Results

On the internal data set, TEERAI‐pre achieved 75.0% accuracy (95% CI, 71.7%–78.4%) for classifying red (unsuitable), yellow (challenging), and green (ideal) zones, with 77.1% precision, 75.5% recall, and 76.2% F1 score. External validation yielded 73.3% accuracy, 74.0% precision, and 74.0% recall. Multiview multimodal integration improved performance. Binary classification (red versus green) showed TEERAI‐pre matched senior experts and outperformed intermediate/junior echocardiologists. Feature‐level fusion outperformed output‐level fusion and single‐view model. Backbone selection and calibration analysis confirmed robust performance.

Conclusions

TEERAI‐pre demonstrates strong performance in transcatheter edge‐to‐edge mitral valve repair preoperative assessment using transthoracic echocardiographic videos and images, supporting more accurate patient selection and enhancing clinical workflow efficiency. Registration URL: clinicaltrials.gov ; Unique Identifier: NCT05508438.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceDeep LearningEchocardiography, TransesophagealMitral ValveMitral Valve InsufficiencyAgedFemaleHumansMaleMultimodal ImagingPredictive Value of TestsPreoperative CareProspective Studies

Stichwörter der Autor:innen

AI‐drivenTEERmultimodalmultiviewvideo vision transformer

Autor:innen und Institutionen

  • State Key Laboratory of Cardiovascular Disease, Department of Echocardiography, National Center for Cardiovascular Diseases, Fuwai Hospital Chinese Academy of Medical Sciences and Peking Union Medical College Beijing Ch…
  • Medical Ultrasound Image Computing (MUSIC) Laboratory, School of Biomedical Engineering, Shenzhen University Medical School Shenzhen University Shenzhen P.R. China.
  • Department of Cardiology, National Center of Gerontology, Beijing Hospital, Institute of Geriatric Medicine Chinese Academy of Medical Sciences Beijing P.R. China.
  • Beijing Jingmei Group General Hospital Beijing China.
  • State Key Laboratory of Cardiovascular Disease, Department of Anesthesiology, National Center for Cardiovascular Diseases, Fuwai Hospital Chinese Academy of Medical Sciences and Peking Union Medical College Beijing Chin…

ORCID-Profile: Wufeng Xue, Fujian Duan

Zitieren

APA

Li, H., Chen, Y., Zhang, J., Guo, Y., Guo, Q., Guo, H., Gong, J., Ni, D., Wang, F., Xue, W., & Duan, F. (2026). TEERAI‐Pre: A Multiview Artificial Intelligence Model for Preoperative Assessment of Transcatheter Edge‐to‐Edge Mitral Valve Repair Using Multiview, Multimodal Echocardiography. Journal of the American Heart Association. https://doi.org/10.1161/jaha.125.044333

Vancouver

Li H, Chen Y, Zhang J, Guo Y, Guo Q, Guo H, et al. TEERAI‐Pre: A Multiview Artificial Intelligence Model for Preoperative Assessment of Transcatheter Edge‐to‐Edge Mitral Valve Repair Using Multiview, Multimodal Echocardiography. Journal of the American Heart Association. 2026. doi:10.1161/jaha.125.044333

BibTeX
@article{Li2026,
  author = {Li, Hui and Chen, Yida and Zhang, Jialin and Guo, Ying and Guo, Qing and Guo, Hongxia and Gong, Junsong and Ni, Dong and Wang, Fang and Xue, Wufeng and Duan, Fujian},
  title = {TEERAI‐Pre: A Multiview Artificial Intelligence Model for Preoperative Assessment of Transcatheter Edge‐to‐Edge Mitral Valve Repair Using Multiview, Multimodal Echocardiography},
  journal = {Journal of the American Heart Association},
  year = {2026},
  doi = {10.1161/jaha.125.044333}
}
Kostenlos starten →