Diagnostic Performance of Unattended Automated Office Blood Pressure Measurement for Hypertension Screening Among People With and Without HIV
Journal of the American Heart Association · 07.10.2025 · 14 (19)
DOI: 10.1161/jaha.125.043957 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Heart Association, erschienen am 07.10.2025. Verfasst von Ruth K Lucinde und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Epidemiology and Demography KEMRI-Wellcome Trust Research Programme Kilifi Kenya. Hauptthemen laut MEDLINE: HIV Infections, Hypertension, Blood Pressure Monitoring, Ambulatory, Blood Pressure Determination. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Wellcome Trust, FIC NIH HHS, NHLBI NIH HHS.
Abstract (Originalsprache)
Background
The diagnostic performance of automated office blood pressure (AOBP) in screening for hypertension in people with HIV (PWH) is not known.
Methods
We conducted a cross‐sectional analysis of baseline data from PWH and people without HIV (PWoH) from the Mwanza HIV&CVD cohort study. We conducted unattended AOBP and 24‐hour ambulatory BP monitoring as recommended by international guidelines. Using average 24‐hour BP as the reference standard, we estimated the prevalence of hypertensive diagnostic phenotypes and calculated measures of diagnostic performance at different diagnostic cutoffs in participants.
Results
We included 959 participants (50.4% PWH and 49.6% PWoH). Characteristics were similar across participant groups. The median age was 44 years (interquartile range, 38–50 years), and 69.8% were women. Overall prevalence of hypertension, based on average 24‐hour ambulatory BP monitoring, was 35.3% using European Society of Hypertension cutoffs and did not differ by HIV infection status. Masked hypertension was present in 25.7% (95% CI, 22.0%–29.8%) of PWH and 26.7% (95% CI, 22.9%–30.8%) of PWoH. The sensitivity of unattended AOBP was 25.7% for PWH (95% CI, 19.3%–33.1%) and 25.7% for PWoH (95% CI, 19.4%–33.0%) with little difference in the area under the receiver‐operating curve by HIV infection status. Based on 24‐hour BP averages, 24.2% of PWH and 21.6% of PWoH had isolated nocturnal hypertension.
Conclusions
More than half of individuals with hypertension on ambulatory BP monitoring, irrespective of their HIV infection status, may be misdiagnosed if unattended AOBP alone is used to screen for hypertension in sub‐Saharan Africa.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Epidemiology and Demography KEMRI-Wellcome Trust Research Programme Kilifi Kenya.
- Center for Global Health, Department of Medicine Weill Cornell Medicine New York NY USA.
- Mwanza Intervention Trials Unit, National Institute of Medical Research Mwanza Tanzania.
- Division of Cardiology, Department of Medicine University of California San Francisco San Francisco CA USA.
- Department of Infectious Disease Epidemiology London School of Hygiene and Tropical Medicine London UK.
- Weill Cornell Center for Sleep Medicine, Departments of Medicine Neurology and Genetic Medicine, Weill Cornell Medical College New York NY USA.
ORCID-Profile: Ruth K Lucinde, Heiner Grosskurth, Ana C Krieger, Myung Hee Lee, Saidi Kapiga, Anthony O Etyang
Förderung
- Wellcome Trust
- FIC NIH HHS
- NHLBI NIH HHS
Zitieren
APA
Lucinde, R. K., Willkens, M., Issarow, B., Fadhil, S., Cichowitz, C., Ayieko, P., Kisigo, G., Venkatraman, S., Grosskurth, H., Krieger, A. C., Devereux, R. B., Lee, M. H., Kapiga, S., Peck, R. N., & Etyang, A. O. (2025). Diagnostic Performance of Unattended Automated Office Blood Pressure Measurement for Hypertension Screening Among People With and Without HIV. Journal of the American Heart Association, 14(19). https://doi.org/10.1161/jaha.125.043957
Vancouver
Lucinde RK, Willkens M, Issarow B, Fadhil S, Cichowitz C, Ayieko P, et al. Diagnostic Performance of Unattended Automated Office Blood Pressure Measurement for Hypertension Screening Among People With and Without HIV. Journal of the American Heart Association. 2025;14(19). doi:10.1161/jaha.125.043957
BibTeX
@article{Lucinde2025,
author = {Lucinde, Ruth K and Willkens, Megan and Issarow, Benson and Fadhil, Salama and Cichowitz, Cody and Ayieko, Philip and Kisigo, Godfrey and Venkatraman, Sara and Grosskurth, Heiner and Krieger, Ana C and Devereux, Richard B and Lee, Myung Hee and Kapiga, Saidi and Peck, Robert N and Etyang, Anthony O},
title = {Diagnostic Performance of Unattended Automated Office Blood Pressure Measurement for Hypertension Screening Among People With and Without HIV},
journal = {Journal of the American Heart Association},
year = {2025},
volume = {14},
number = {19},
doi = {10.1161/jaha.125.043957}
}
EUVIMED