Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience

Naychi Lwin iD, Caroline Ovaert iD, Sophie Malekzadeh-Milani iD, Paul Padovani iD, Thomas Krasemann iD, Stanimir Georgiev iD, Oscar Werner iD, Ali Houeijeh iD, Stéphanie Douchin iD, Peter Kramer iD, Lorenzo Scarduelli, Lisa Bianco iD und 9 weitere

Journal of the American Heart Association · 21.10.2025 · 14 (20)

DOI: 10.1161/jaha.125.043468 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of the American Heart Association, erschienen am 21.10.2025. Verfasst von Naychi Lwin und 20 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology and Pediatric Cardiac Surgery Nantes Université, CHU Nantes Nantes France. Hauptthemen laut MEDLINE: Cardiac Catheterization, Ductus Arteriosus, Patent, Off-Label Use, Septal Occluder Device. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transcatheter patent ductus arteriosus (PDA) closure can be challenging in cases of large PDA, complex anatomy, and small patient size. We aimed to assess the feasibility, efficacy and safety of the off‐label use of the multifunctional occluder in transcatheter PDA closure.

Methods

A retrospective analysis was conducted on patients who underwent transcatheter PDA closure with the multifunctional occluder in 14 pediatric cardiology centers (5 countries) from 2018 to 2025.

Results

A total of 77 procedures were performed on 75 patients, including 5 adults (6.7%). Among the 70 children (93.3%; median age: 0.8 years [range, 0.1–10 years], median procedural weight: 6.9 kg [range, 2.1–32.0 kg]), 35 (50.0%) weighed ≤6 kg (median procedural weight: 4.0 kg [range, 2.1–5.9 kg]). The PDA was large, with a minimal ductal diameter of 3.8 mm (range, 1.5–7.0 mm), short in 54.5%, and unrestrictive with increased pulmonary artery pressures in 51.6% of patients. The morphology was predominantly conical (Krichenko type A: 51.9%), with window‐type or complex morphologies representing 26.7% (Type B: 18.2%, Type D: 7.8%). Both arterial and venous femoral accesses were obtained in 87.0% cases, with deployment being antegrade in 77.9% and retrograde in 22.1%. Successful device deployment and release were achieved in 74 cases (96.1%). The rate of major adverse events was 5.2% including 1 early (1.3%) and 3 late complications (3.9%). No other adverse events were reported.

Conclusions

The off‐label use of the multifunctional occluder device is a promising option for transcatheter PDA closure, demonstrating safety and efficacy in this series.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac CatheterizationDuctus Arteriosus, PatentOff-Label UseSeptal Occluder DeviceAdultChildChild, PreschoolFemaleHumansInfantInfant, NewbornMaleFeasibility StudiesProsthesis DesignRetrospective StudiesTreatment Outcome

Stichwörter der Autor:innen

Doppler echocardiographycongenital heart diseaseoff labeloutcomespediatric cardiology

Autor:innen und Institutionen

  • Department of Pediatric Cardiology and Pediatric Cardiac Surgery Nantes Université, CHU Nantes Nantes France.
  • Pediatric and Congenital Cardiology Department APHM La Timone Hospital Marseille France.
  • M3C-Necker, Department of Pediatric and Congenital Cardiology Hôpital Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP) Paris France.
  • Department of Pediatric Cardiology and Pediatric Cardiac Surgery Nantes Université, CHU Nantes, INSERM Nantes France.
  • Department of Paediatric Cardiology Sophia Children's Hospital Rotterdam The Netherlands.
  • Department of Congenital Heart Disease and Pediatric Cardiology German Heart Center Munich at the Technical University of Munich Germany.

ORCID-Profile: Naychi Lwin, Caroline Ovaert, Sophie Malekzadeh-Milani, Paul Padovani, Thomas Krasemann, Stanimir Georgiev, Oscar Werner, Ali Houeijeh, Stéphanie Douchin, Peter Kramer, Lisa Bianco, Céline Grunenwald, Sébastien Hascoët, Zakaria Jalal, Nadir Benbrik, Iñaki Navarro Castellanos, Stephan Schubert, Alain Fraisse, Alban-Elouen Baruteau

Zitieren

APA

Lwin, N., Ovaert, C., Malekzadeh-Milani, S., Padovani, P., Krasemann, T., Georgiev, S., Werner, O., Houeijeh, A., Douchin, S., Kramer, P., Scarduelli, L., Bianco, L., Grunenwald, C., Hascoët, S., Jalal, Z., Benbrik, N., Lefort, B., Navarro Castellanos, I., Schubert, S., …, & Baruteau, A. E. (2025). Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience. Journal of the American Heart Association, 14(20). https://doi.org/10.1161/jaha.125.043468

Vancouver

Lwin N, Ovaert C, Malekzadeh-Milani S, Padovani P, Krasemann T, Georgiev S, et al. Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience. Journal of the American Heart Association. 2025;14(20). doi:10.1161/jaha.125.043468

BibTeX
@article{Lwin2025,
  author = {Lwin, Naychi and Ovaert, Caroline and Malekzadeh-Milani, Sophie and Padovani, Paul and Krasemann, Thomas and Georgiev, Stanimir and Werner, Oscar and Houeijeh, Ali and Douchin, Stéphanie and Kramer, Peter and Scarduelli, Lorenzo and Bianco, Lisa and Grunenwald, Céline and Hascoët, Sébastien and Jalal, Zakaria and Benbrik, Nadir and Lefort, Bruno and Navarro Castellanos, Iñaki and Schubert, Stephan and Fraisse, Alain and Baruteau, Alban-Elouen},
  title = {Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience},
  journal = {Journal of the American Heart Association},
  year = {2025},
  volume = {14},
  number = {20},
  doi = {10.1161/jaha.125.043468}
}
Kostenlos starten →