EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Long‐Term Durability of Transcatheter Aortic Valve Prostheses in Patients With Bicuspid Versus Tricuspid Aortic Valve

Hong-De Li iD, Wei-Ya Li, Jun-Li Li, Shi-Qin Peng, Yuan Feng iD, Yong Peng iD, Jia-Fu Wei iD, Zhen-Gang Zhao iD, Tian-Yuan Xiong iD, Yuan-Wei Xiang Ou, Yan Wang iD, Qing Li und 7 weitere

Journal of the American Heart Association · 2024

DOI: 10.1161/jaha.124.035772 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of the American Heart Association, 2024. Verfasst von Hong-De Li und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology West China Hospital, Sichuan University Chengdu People's Republic of China. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Bicuspid Aortic Valve Disease, Heart Valve Prosthesis, Bioprosthesis. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Currently, there is a lack of evidence for the long‐term bioprosthetic valve durability of patients with bicuspid aortic valve (BAV) following transcatheter aortic valve replacement (TAVR). Methods and Results This study aimed to evaluate hemodynamic outcome, structural valve deterioration, and bioprosthetic valve failure during long‐term follow‐up after TAVR in patients with BAV versus patients with tricuspid aortic valve (TAV). Patients with BAV and TAV who underwent TAVR between 2012 and 2020, with echocardiography followed for at least 3 years, were included. Baseline characteristics, long‐term valve hemodynamic performance, structural valve deterioration, and bioprosthetic valve failure were compared between patients with BAV and TAV. A total of 170 patients with BAV and 145 patients with TAV were included. The mean duration of follow‐up for patients with BAV and TAV was 5.2±1.8 and 5.0±1.7 years. No significant differences were observed in the rates of structural valve deterioration and bioprosthetic valve failure between patients with BAV and TAV: structural valve deterioration, BAV 20 (11.8%) versus TAV 16 (11.0%) at last follow‐up ( P =0.861); bioprosthetic valve failure, BAV 3 (1.8%) versus TAV 7 (4.8%) at last follow‐up ( P =0.196). More than moderate intravalvular aortic regurgitation (1.8% versus 4.8%, P =0.196) and paravalvular leak (6.5% versus 3.4%, P =0.305) were rare in both patients with BAV and patients with TAV.

Conclusions

This study indicated satisfactory long‐term valve durability of TAVR in patients with BAV. Comparable hemodynamic outcome, structural valve deterioration, and bioprosthetic valve failure could be achieved in patients with BAV and TAV during long‐term follow‐up after TAVR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementBicuspid Aortic Valve DiseaseHeart Valve ProsthesisBioprosthesisAortic ValveHemodynamicsProsthesis FailureHumansFemaleMaleAgedAged, 80 and overTime FactorsAortic Valve StenosisProsthesis DesignRetrospective StudiesHeart Valve DiseasesTreatment OutcomeFollow-Up StudiesEchocardiography

Stichwörter der Autor:innen

bicuspid aortic valvestructural valve degenerationtranscatheter aortic valve replacementvalve durability

Autor:innen und Institutionen

  • Department of Cardiology West China Hospital, Sichuan University Chengdu People's Republic of China.
  • Laboratory of Cardiac Structure and Function, Institute of Cardiovascular Diseases West China Hospital, Sichuan University Chengdu People's Republic of China.
  • Department of Geriatrics West China Hospital, Sichuan University Chengdu People's Republic of China.

ORCID-Profile: Hong-De Li, Yuan Feng, Yong Peng, Jia-Fu Wei, Zhen-Gang Zhao, Tian-Yuan Xiong, Yan Wang, Hao-Ran Yang, Qi Liu, Mao Chen

Zitieren

APA

Li, H. D., Li, W. Y., Li, J. L., Peng, S. Q., Feng, Y., Peng, Y., Wei, J. F., Zhao, Z. G., Xiong, T. Y., Ou, Y. X., Wang, Y., Li, Q., Yang, H. R., Song, C. X., Yao, Y. J., Zhu, Z. K., Liu, Q., Wang, X., & Chen, M. (2024). Long‐Term Durability of Transcatheter Aortic Valve Prostheses in Patients With Bicuspid Versus Tricuspid Aortic Valve. Journal of the American Heart Association. https://doi.org/10.1161/jaha.124.035772

Vancouver

Li HD, Li WY, Li JL, Peng SQ, Feng Y, Peng Y, et al. Long‐Term Durability of Transcatheter Aortic Valve Prostheses in Patients With Bicuspid Versus Tricuspid Aortic Valve. Journal of the American Heart Association. 2024. doi:10.1161/jaha.124.035772

BibTeX
@article{Li2024,
  author = {Li, Hong-De and Li, Wei-Ya and Li, Jun-Li and Peng, Shi-Qin and Feng, Yuan and Peng, Yong and Wei, Jia-Fu and Zhao, Zhen-Gang and Xiong, Tian-Yuan and Ou, Yuan-Wei Xiang and Wang, Yan and Li, Qing and Yang, Hao-Ran and Song, Cheng-Xiang and Yao, Yi-Jun and Zhu, Zhong-Kai and Liu, Qi and Wang, Xi and Chen, Mao},
  title = {Long‐Term Durability of Transcatheter Aortic Valve Prostheses in Patients With Bicuspid Versus Tricuspid Aortic Valve},
  journal = {Journal of the American Heart Association},
  year = {2024},
  doi = {10.1161/jaha.124.035772}
}
Kostenlos starten →