Impact of Defibrillator Electrode Placement on Outcome of Electrical Cardioversion of Atrial Fibrillation: A Pilot Observational Study
Journal of the American Heart Association · 2024
DOI: 10.1161/jaha.123.034817 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of the American Heart Association, 2024. Verfasst von Luai Madanat und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, William Beaumont University Hospital Corewell Health East Royal Oak MI USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Electric Countershock. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background Anterior–posterior electrode placement is preferred in electrical cardioversion of atrial fibrillation. However, the optimal anterior–posterior electrode position in relation to the heart is not studied. Methods and Results We performed a prospective observational study on patients presenting for cardioversion of atrial fibrillation. Electrodes were placed in the anterior–posterior position and shock was delivered in a step‐up approach (100 J→200 J→360 J). Fluoroscopic images were obtained, and distances were measured from points A, midanterior electrode; and B, midposterior electrode, to midpoint of the cardiac silhouette. Patients requiring one 100 J shock for cardioversion success (group I) were compared with those requiring >1 shock/100 J (group II). Logistic regression was used to determine the impact of electrode distance on low energy (100 J) cardioversion success. Computed tomography scans from this cohort were analyzed for anatomic landmark correlation to the cardiac silhouette. Of the 87 patients included, 54 (62%) comprised group I and 33 (38%) group II. Group I had significantly lower distances from the mid–cardiac silhouette to points A (5.0±2.4 versus 7.4±3.3 cm; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, William Beaumont University Hospital Corewell Health East Royal Oak MI USA.
- Oakland University William Beaumont School of Medicine Rochester MI USA.
- Department of Biostatistics and Health Informatics Beaumont Research Institute Royal Oak MI USA.
- University of Virginia Charlottesville VA USA.
ORCID-Profile: Luai Madanat, Josh France, Nolan Shoukri, Ilana Kutinsky, Brian Williamson, Elvis Cami, Michael Gallagher, Richard Bloomingdale, Simon Dixon, Nishaki Mehta
Zitieren
APA
Madanat, L., France, J., Shoukri, N., Bilolikar, A. N., Walsh, D., Kutinsky, I., Gundlapalli, S., Zhao, L., Goel, A., Williamson, B., Cami, E., Gallagher, M., Bloomingdale, R., Dixon, S., Haines, D., & Mehta, N. (2024). Impact of Defibrillator Electrode Placement on Outcome of Electrical Cardioversion of Atrial Fibrillation: A Pilot Observational Study. Journal of the American Heart Association. https://doi.org/10.1161/jaha.123.034817
Vancouver
Madanat L, France J, Shoukri N, Bilolikar AN, Walsh D, Kutinsky I, et al. Impact of Defibrillator Electrode Placement on Outcome of Electrical Cardioversion of Atrial Fibrillation: A Pilot Observational Study. Journal of the American Heart Association. 2024. doi:10.1161/jaha.123.034817
BibTeX
@article{Madanat2024,
author = {Madanat, Luai and France, Josh and Shoukri, Nolan and Bilolikar, Abhay N and Walsh, Daniel and Kutinsky, Ilana and Gundlapalli, Sujana and Zhao, Lili and Goel, Anil and Williamson, Brian and Cami, Elvis and Gallagher, Michael and Bloomingdale, Richard and Dixon, Simon and Haines, David and Mehta, Nishaki},
title = {Impact of Defibrillator Electrode Placement on Outcome of Electrical Cardioversion of Atrial Fibrillation: A Pilot Observational Study},
journal = {Journal of the American Heart Association},
year = {2024},
doi = {10.1161/jaha.123.034817}
}
EUVIMED