EUVIMEDEUVIMED entdecken
Open Access

Installation of Public Access Defibrillators for Out‐of‐Hospital Cardiac Arrests: Identifying Suitable Locations by Using a Geographic Information System

Chen-Bin Chen iD, Ming-Fang Wang iD, Chen-June Seak iD, Liang-Tien Chien, Chung-Hsien Chaou, Yu-Tung Chang iD, Chip-Jin Ng iD, Li-Heng Tsai iD, Chien-Hsiung Huang iD, Tzu-Heng Cheng iD, Chieh-Ching Yen, Pei-Li Chung und 1 weitere

Journal of the American Heart Association · 2024

DOI: 10.1161/jaha.123.034045 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Heart Association, 2024. Verfasst von Chen-Bin Chen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Chang Gung Memorial Hospital, Linkou and College of Medicine Chang Gung University Taoyuan Taiwan. Hauptthemen laut MEDLINE: Out-of-Hospital Cardiac Arrest, Defibrillators, Geographic Information Systems. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Survival following an out‐of‐hospital cardiac arrest depends on prompt defibrillation. Despite the efforts made to install automated external defibrillators (AEDs) in crowded areas, their usage rate remains suboptimal. This study evaluated the efficiency of installing AEDs at key landmarks in Taoyuan City to enhance accessibility and usage. METHODS AND RESULTS This retrospective cohort study analyzed nontraumatic public out‐of‐hospital cardiac arrest cases in Taoyuan City from 2017 to 2021, using data from the Taoyuan Fire Department and a regional registry. AED data were collected for 1163 devices. A geographic information system mapped target locations within the city, and real‐world walking routes were examined to assess coverage. The primary outcome was actual coverage and the coverage efficiency ratio, calculated as the actual coverage divided by the number of facilities at a location. The coverage efficiency ratio compared the coverage efficiency of target locations with existing public access defibrillators (PADs). Top locations for superior coverage in both downtown and outside downtown areas were bus stops and convenience stores (7‐Eleven and FamilyMart), which outperformed existing PADs. Convenience stores had a higher coverage efficiency ratio than the public service sector. Bus stops showed high AED usage rates before ambulance arrival.

Conclusions

The current PAD locations in Taoyuan City offer limited coverage, which highlights the need for strategically installed AEDs, particularly in convenience stores. Policymakers should consider using the cultural relevance and accessibility of convenience stores, particularly 7‐Eleven branches, to enhance AED usage rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Out-of-Hospital Cardiac ArrestDefibrillatorsGeographic Information SystemsHumansRetrospective StudiesMaleFemaleChinaElectric CountershockHealth Services AccessibilityMiddle AgedCardiopulmonary ResuscitationEmergency Medical ServicesRegistriesAged

Stichwörter der Autor:innen

automated external defibrillatorsemergency medical servicesgeographic information systemout‐of‐hospital cardiac arrestpublic access defibrillators

Autor:innen und Institutionen

  • Department of Emergency Medicine, Chang Gung Memorial Hospital, Linkou and College of Medicine Chang Gung University Taoyuan Taiwan.
  • Department of Emergency Medicine New Taipei Municipal TuCheng Hospital and Chang Gung University New Taipei City Taiwan.
  • Department of Emergency Medicine Chang Gung Memorial Hospital Taipei Branch Taipei Taiwan.
  • Graduate Institute of Management, College of Management, Chang Gung University Taoyuan Taiwan.
  • Taoyuan Fire Department Taoyuan Taiwan.
  • College of Health Technology National Taipei University of Nursing and Health Sciences Taipei Taiwan.

ORCID-Profile: Chen-Bin Chen, Ming-Fang Wang, Chen-June Seak, Yu-Tung Chang, Chip-Jin Ng, Li-Heng Tsai, Chien-Hsiung Huang, Tzu-Heng Cheng, Cheng-Yu Chien

Zitieren

APA

Chen, C. B., Wang, M. F., Seak, C. J., Chien, L. T., Chaou, C. H., Chang, Y. T., Ng, C. J., Tsai, L. H., Huang, C. H., Cheng, T. H., Yen, C. C., Chung, P. L., & Chien, C. Y. (2024). Installation of Public Access Defibrillators for Out‐of‐Hospital Cardiac Arrests: Identifying Suitable Locations by Using a Geographic Information System. Journal of the American Heart Association. https://doi.org/10.1161/jaha.123.034045

Vancouver

Chen CB, Wang MF, Seak CJ, Chien LT, Chaou CH, Chang YT, et al. Installation of Public Access Defibrillators for Out‐of‐Hospital Cardiac Arrests: Identifying Suitable Locations by Using a Geographic Information System. Journal of the American Heart Association. 2024. doi:10.1161/jaha.123.034045

BibTeX
@article{Chen2024,
  author = {Chen, Chen-Bin and Wang, Ming-Fang and Seak, Chen-June and Chien, Liang-Tien and Chaou, Chung-Hsien and Chang, Yu-Tung and Ng, Chip-Jin and Tsai, Li-Heng and Huang, Chien-Hsiung and Cheng, Tzu-Heng and Yen, Chieh-Ching and Chung, Pei-Li and Chien, Cheng-Yu},
  title = {Installation of Public Access Defibrillators for Out‐of‐Hospital Cardiac Arrests: Identifying Suitable Locations by Using a Geographic Information System},
  journal = {Journal of the American Heart Association},
  year = {2024},
  doi = {10.1161/jaha.123.034045}
}
Kostenlos starten →