EUVIMEDEUVIMED entdecken
Crossref

Abstract FR422: Home versus Office Blood Pressure Measurement, Enhancing Accuracy and Patient Care

Andrea Price, Sandy Robertson, Hazel Tapp, Jacqueline Halladay, Doyle M Cummings

Hypertension · 2026-10 · 83 (Suppl_1)

DOI: 10.1161/hyp.83.suppl_1.fr422 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hypertension, 2026-10. Verfasst von Andrea Price und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate blood pressure (BP) measurement is essential for appropriate diagnosis, staging and management of hypertension. The 2025 AHA/ACC guideline for optimal BP control and cardiovascular risk reduction define Stage 2 hypertension as ≥140/90 mmHg and recommend starting antihypertensive therapy, often a fixed-dose combination, alongside lifestyle modifications. Office based BP readings often differ from home based measurements, which may lead to misclassification and inappropriate treatment. Despite increasing use of multiple BP measurement modalities in large, pragmatic trials, baseline discrepancies between office and home readings prior to intervention remain understudied.

Objective

Compare baseline office BP with home based BP readings collected during the first 2 weeks of a hypertension randomized trial, prior to intervention, and to compare measurement modalities for clinical decision making.

Design

In 3 NC family medicine clinics we compared 1) most recent EHR-recorded office BP prior to trial entry, 2) research-grade office BP obtained for eligibility, and 3) home based BP readings transmitted via cellular-enabled home BP monitor during the first 2 weeks following enrollment before intervention. Descriptive statistics and paired comparisons evaluated differences in systolic BP (SBP), focusing on discrepancies ≥10 mmHg between office and home readings. Population: Seventy-three patients with uncontrolled hypertension at baseline (office BP >140/90 mmHg) who completed research-grade office BP assessment and obtained ≥10 home based BP readings within the first 2 weeks of study enrollment; mean home SBP was computed.

Intervention

Participants received a cellular-enabled ambulatory BP monitoring device for home use. SBP readings were collected for 2 weeks prior to the first study visit. Outcome Measures: The primary outcome was the percentage of patients with a mean home based SBP ≥10 mmHg lower than office readings. Secondary outcome was the percentage of patients who had an average home based SBP ≤140mmHg with an average office based systolic >140mmHg.

Results

Thirty-eight patients (52.1%) showed ≥10 mmHg lower average SBP at home compared to office. The average difference in SBP was -22.9 mmHg (± 13.4). Of these 38 patients, 19 had an average home-SBP 140mmHg. The average difference in SBP for this sub-group was -28.2 mmHg (± 15.6). Outcomes: Substantial differences between office and home based BP measurements exist prior to intervention in a real world hypertension trial. Home based BP monitoring may more accurately reflect BP control, with important implications for accurate diagnosis, clinical decision making, and treatment intensification as well as trial eligibility. These findings support incorporating home based BP assessment into clinical workflows to reduce misclassification and optimize hypertension care.

Zitieren

APA

Price, A., Robertson, S., Tapp, H., Halladay, J., & Cummings, D. M. (2026). Abstract FR422: Home versus Office Blood Pressure Measurement, Enhancing Accuracy and Patient Care. Hypertension, 83(Suppl_1). https://doi.org/10.1161/hyp.83.suppl_1.fr422

Vancouver

Price A, Robertson S, Tapp H, Halladay J, Cummings DM. Abstract FR422: Home versus Office Blood Pressure Measurement, Enhancing Accuracy and Patient Care. Hypertension. 2026;83(Suppl_1). doi:10.1161/hyp.83.suppl_1.fr422

BibTeX
@article{Price2026,
  author = {Price, Andrea and Robertson, Sandy and Tapp, Hazel and Halladay, Jacqueline and Cummings, Doyle M},
  title = {Abstract FR422: Home versus Office Blood Pressure Measurement, Enhancing Accuracy and Patient Care},
  journal = {Hypertension},
  year = {2026},
  volume = {83},
  number = {Suppl_1},
  doi = {10.1161/hyp.83.suppl_1.fr422}
}
Kostenlos starten →