EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Dynamic Change of Coronary Artery Geometry After Bioadaptor Implantation: A Single-blind Randomized Controlled Trial

Cheng-Hsuan Tsai iD, Han-Hsuan Chu, Ching-Chang Huang iD, Chih-Fan Yeh iD, Ying-Hsien Chen iD, Mao-Shin Lin iD, Tsung-Yu Ko, Chun-Kai Chen, Yu-Cheng Huang iD, Pin-Yi Chiang, Wen-Jeng Lee iD, Hsien-Li Kao iD

Circulation: Cardiovascular Interventions · 2026-02 · 19 (2)

DOI: 10.1161/circinterventions.125.016191 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Circulation: Cardiovascular Interventions, 2026-02. Verfasst von Cheng-Hsuan Tsai und 11 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei (C.-H.T.). Hauptthemen laut MEDLINE: Coronary Vessels, Percutaneous Coronary Intervention, Drug-Eluting Stents, Coronary Artery Disease. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The DynamX bioadaptor, a novel coronary implant, is designed to restore vessel function when the thin polymer coating covering the helical strands resorbs 6 months post-percutaneous coronary intervention. We aimed to evaluate vessel conformability 1 year after percutaneous coronary intervention with the bioadaptor, compared with conventional drug-eluting stents (DESs). METHODS: Vessel segments were 1:1 randomized to a novolimus-eluting bioadaptor or a durable polymer novolimus-eluting second-generation DES. Coronary computed tomography angiography was performed at 1 and 12 months post-implantation, and the 3-dimensional geometry of the treated segments in coronary computed tomography angiography was analyzed. The primary outcome was the change in dynamic vessel geometry, including curvature flexibility (bending motion), torsion flexibility (twisting motion), and path flexibility (3-dimensional motion) of the treated segment during the cardiac cycle. RESULTS: A total of 48 vessel segments in 48 patients were randomized, with 24 receiving bioadaptor and 24 receiving DES. In within-group paired analyses, the bioadaptor group showed a significant improvement in torsion flexibility from 1 to 12 months, whereas no significant change was observed in the DES group. Although curvature and path flexibility increased numerically in the bioadaptor group, these within-group differences were not statistically significant. However, when comparing the magnitude of change between groups, the increase in path flexibility was significantly greater with the bioadaptor than with DES, indicating a superior restoration of 3-dimensional vessel motion. CONCLUSIONS: The novel bioadaptor technology demonstrated favorable restoration of 3-dimensional dynamic geometry of the treated vessel segment 12 months after implantation, in comparison with traditional DES. These initial mechanistic findings suggest a potential explanation for the favorable clinical outcomes observed in prior trials, and our analytical approach may offer new insights to guide future vascular implant designs and evaluations. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04936191.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary VesselsPercutaneous Coronary InterventionDrug-Eluting StentsCoronary Artery DiseaseAbsorbable ImplantsHumansCoronary AngiographyTime FactorsTreatment OutcomeProsthesis DesignSingle-Blind MethodMaleFemaleAgedComputed Tomography Angiography

Stichwörter der Autor:innen

coronary artery diseasedrug-eluting stentsinflammationpercutaneous coronary interventionpolymers

Autor:innen und Institutionen

  • Graduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei (C.-H.T.).
  • Division of Cardiology, Department of Internal Medicine and Cardiovascular Center, National Taiwan University Hospital, Taipei (C.-H.T., C.C.H., C.F.Y., Y.H.C., M.S.L., T.-Y.K., C.-K.C., H.-L.K.).
  • Department of Medical Imaging, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei (H.-H.C., Y.-C.H., P.-Y.C., W.-J.L.).

ORCID-Profile: Cheng-Hsuan Tsai, Ching-Chang Huang, Chih-Fan Yeh, Ying-Hsien Chen, Mao-Shin Lin, Yu-Cheng Huang, Wen-Jeng Lee, Hsien-Li Kao

Zitieren

APA

Tsai, C. H., Chu, H. H., Huang, C. C., Yeh, C. F., Chen, Y. H., Lin, M. S., Ko, T. Y., Chen, C. K., Huang, Y. C., Chiang, P. Y., Lee, W. J., & Kao, H. L. (2026). Dynamic Change of Coronary Artery Geometry After Bioadaptor Implantation: A Single-blind Randomized Controlled Trial. Circulation: Cardiovascular Interventions, 19(2). https://doi.org/10.1161/circinterventions.125.016191

Vancouver

Tsai CH, Chu HH, Huang CC, Yeh CF, Chen YH, Lin MS, et al. Dynamic Change of Coronary Artery Geometry After Bioadaptor Implantation: A Single-blind Randomized Controlled Trial. Circulation: Cardiovascular Interventions. 2026;19(2). doi:10.1161/circinterventions.125.016191

BibTeX
@article{Tsai2026,
  author = {Tsai, Cheng-Hsuan and Chu, Han-Hsuan and Huang, Ching-Chang and Yeh, Chih-Fan and Chen, Ying-Hsien and Lin, Mao-Shin and Ko, Tsung-Yu and Chen, Chun-Kai and Huang, Yu-Cheng and Chiang, Pin-Yi and Lee, Wen-Jeng and Kao, Hsien-Li},
  title = {Dynamic Change of Coronary Artery Geometry After Bioadaptor Implantation: A Single-blind Randomized Controlled Trial},
  journal = {Circulation: Cardiovascular Interventions},
  year = {2026},
  volume = {19},
  number = {2},
  doi = {10.1161/circinterventions.125.016191}
}
Kostenlos starten →