EUVIMEDEUVIMED entdecken
Klinische StudieMultizentrische Studie

Clinical Experience With a Novel Percutaneous LV Assist Device in High-Risk PCI: Primary Results From the SUPPORT I Study

David E Kandzari iD, Andrea Mignatti iD, Annapoorna Kini iD, Garrett Wong, Gagan Singh iD, Azeem Latib iD, Ricardo Costa, Carlos M Campos iD, Alexandre Abizaid iD

Circulation: Cardiovascular Interventions · 2026

DOI: 10.1161/circinterventions.125.016010 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Circulation: Cardiovascular Interventions, 2026. Verfasst von David E Kandzari und 8 weiteren Autor:innen. Beteiligte Einrichtung: Piedmont Heart Institute, Atlanta, GA (D.E.K.). Hauptthemen laut MEDLINE: Coronary Artery Disease, Heart-Assist Devices, Hemodynamics, Percutaneous Coronary Intervention. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: An early feasibility study was conducted to evaluate the performance of a low-profile, microaxial percutaneous ventricular assist device (pVAD; Supira Medical, Los Gatos, CA) capable of up to 5.5 L/min flow to provide hemodynamic support in high-risk percutaneous intervention (PCI). METHODS: A prospective, single-arm feasibility study using the Supira pVAD in high-risk PCI was performed at 4 centers in the United States. The primary feasibility end point was defined as successful initiation and maintenance of hemodynamic support without sustained hypotension or need for alternative mechanical circulatory support. The primary safety end point was the occurrence of major device-related adverse events attributed to the study device or procedure from the time of device insertion to removal. RESULTS: Fifteen patients underwent elective high-risk PCI with hemodynamic support using the Supira pVAD system. Multivessel PCI was performed in 80% of cases, including unprotected left main revascularization (67%) and atherectomy and intravascular lithotripsy (60%). Technical and procedural success rates were 93.3% and 86.7%, respectively. The primary feasibility end point was achieved in all 15 patients (100%). The primary safety end point occurred in 1 patient (6.7%). By 90 days, there were 2 deaths unrelated to the study device. There were no bleeding events, vascular/limb complications requiring intervention, cardiac structural/valve injury, or stroke attributed to the study device. CONCLUSIONS: As an early feasibility study, treatment with the Supira pVAD demonstrated favorable performance and device-related safety. These findings add to existing experience with the Supira pVAD to support a forthcoming pivotal trial in high-risk PCI. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT06087575.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery DiseaseHeart-Assist DevicesHemodynamicsPercutaneous Coronary InterventionVentricular Function, LeftAgedFemaleHumansMaleMiddle AgedFeasibility StudiesProspective StudiesProsthesis DesignRecovery of FunctionRisk FactorsTime FactorsTreatment OutcomeUnited States

Stichwörter der Autor:innen

atherectomycathetershypotensionlithotripsypercutaneous coronary intervention

Autor:innen und Institutionen

  • Piedmont Heart Institute, Atlanta, GA (D.E.K.).
  • Division of Cardiology, Montefiore Medical Center, Albert Einstein College of Medicine, The Bronx, NY (A.M., A.L.).
  • Mt. Sinai Hospital, NY (A.K.).
  • Division of Cardiology, University of California Davis Medical Center, Sacramento (G.W., G.S.).
  • Institute Dante Pazzanese of Cardiology, São Paulo, Brazil (R.C.).
  • Heart Institute of the University of São Paulo, Brazil (C.M.C., A.A.).

ORCID-Profile: David E Kandzari, Andrea Mignatti, Annapoorna Kini, Gagan Singh, Azeem Latib, Carlos M Campos, Alexandre Abizaid

Zitieren

APA

Kandzari, D. E., Mignatti, A., Kini, A., Wong, G., Singh, G., Latib, A., Costa, R., Campos, C. M., & Abizaid, A. (2026). Clinical Experience With a Novel Percutaneous LV Assist Device in High-Risk PCI: Primary Results From the SUPPORT I Study. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.125.016010

Vancouver

Kandzari DE, Mignatti A, Kini A, Wong G, Singh G, Latib A, et al. Clinical Experience With a Novel Percutaneous LV Assist Device in High-Risk PCI: Primary Results From the SUPPORT I Study. Circulation: Cardiovascular Interventions. 2026. doi:10.1161/circinterventions.125.016010

BibTeX
@article{Kandzari2026,
  author = {Kandzari, David E and Mignatti, Andrea and Kini, Annapoorna and Wong, Garrett and Singh, Gagan and Latib, Azeem and Costa, Ricardo and Campos, Carlos M and Abizaid, Alexandre},
  title = {Clinical Experience With a Novel Percutaneous LV Assist Device in High-Risk PCI: Primary Results From the SUPPORT I Study},
  journal = {Circulation: Cardiovascular Interventions},
  year = {2026},
  doi = {10.1161/circinterventions.125.016010}
}
Kostenlos starten →