Prognostic Impact of Left Atrial Appendage Patency After Device Closure
Circulation: Cardiovascular Interventions · 2024-05 · 17 (5)
DOI: 10.1161/circinterventions.123.013579 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Circulation: Cardiovascular Interventions, 2024-05. Verfasst von Mu Chen und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, China. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation, Ischemic Attack, Transient, Stroke. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: The prognostic impact of left atrial appendage (LAA) patency, including those with and without visible peri-device leak (PDL), post–LAA closure in patients with atrial fibrillation, remains elusive. METHODS: Patients with atrial fibrillation implanted with the WATCHMAN 2.5 device were prospectively enrolled. The device surveillance by cardiac computed tomography angiography was performed at 3 months post-procedure. Adverse events, including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular death, all-cause death, and the combined major adverse events (MAEs), were compared between patients with complete closure and LAA patency. RESULTS: Among 519 patients with cardiac computed tomography angiography surveillance at 3 months post–LAA closure, 271 (52.2%) showed complete closure, and LAA patency was detected in 248 (47.8%) patients, including 196 (37.8%) with visible PDL and 52 (10.0%) without visible PDL. During a median of 1193 (787–1543) days follow-up, the presence of LAA patency was associated with increased risks of stroke/TIA (adjusted hazard ratio for baseline differences, 3.22 [95% CI, 1.17–8.83]; P =0.023) and MAEs (adjusted hazard ratio, 1.12 [95% CI, 1.06–1.17]; P =0.003). Specifically, LAA patency with visible PDL was associated with increased risks of stroke/TIA (hazard ratio, 3.66 [95% CI, 1.29–10.42]; P =0.015) and MAEs (hazard ratio, 3.71 [95% CI, 1.71–8.07]; P =0.001), although LAA patency without visible PDL showed higher risks of MAEs (hazard ratio, 3.59 [95% CI, 1.28–10.09]; P =0.015). Incidences of stroke/TIA (2.8% versus 3.0% versus 6.7% versus 22.2%; P =0.010), cardiovascular death (0.9% versus 0% versus 1.7% versus 11.1%; P =0.005), and MAEs (4.6% versus 9.0% versus 11.7% versus 22.2%; P =0.017) increased with larger PDL (0, >0 to ≤3, >3 to ≤5, or >5 mm). Older age and discontinuing antiplatelet therapy at 6 months were independent predictors of stroke/TIA and MAEs in patients with LAA patency. CONCLUSIONS: LAA patency detected by cardiac computed tomography angiography at 3 months post–LAA closure is associated with unfavorable prognosis in patients with atrial fibrillation implanted with WATCHMAN 2.5 device. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03788941.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, China.
ORCID-Profile: Mu Chen, Peng-Cheng Yao, Qun-Shan Wang, Yi-Chi Yu, Wei Li, Rui Zhang, Bin-Feng Mo, Ming-Zhe Zhao, Yi Yu, Yan Zhao, Chang-Qi Gong, Yi-Gang Li
Zitieren
APA
Chen, M., Yao, P. C., Fei, Z. T., Wang, Q. S., Yu, Y. C., Zhang, P. P., Li, W., Zhang, R., Mo, B. F., Zhao, M. Z., Yu, Y., Yang, M., Zhao, Y., Gong, C. Q., Sun, J., & Li, Y. G. (2024). Prognostic Impact of Left Atrial Appendage Patency After Device Closure. Circulation: Cardiovascular Interventions, 17(5). https://doi.org/10.1161/circinterventions.123.013579
Vancouver
Chen M, Yao PC, Fei ZT, Wang QS, Yu YC, Zhang PP, et al. Prognostic Impact of Left Atrial Appendage Patency After Device Closure. Circulation: Cardiovascular Interventions. 2024;17(5). doi:10.1161/circinterventions.123.013579
BibTeX
@article{Chen2024,
author = {Chen, Mu and Yao, Peng-Cheng and Fei, Zhen-Tao and Wang, Qun-Shan and Yu, Yi-Chi and Zhang, Peng-Pai and Li, Wei and Zhang, Rui and Mo, Bin-Feng and Zhao, Ming-Zhe and Yu, Yi and Yang, Mei and Zhao, Yan and Gong, Chang-Qi and Sun, Jian and Li, Yi-Gang},
title = {Prognostic Impact of Left Atrial Appendage Patency After Device Closure},
journal = {Circulation: Cardiovascular Interventions},
year = {2024},
volume = {17},
number = {5},
doi = {10.1161/circinterventions.123.013579}
}
EUVIMED