Conduit Flow Compensates for Impaired Left Atrial Passive and Booster Functions in Advanced Diastolic Dysfunction
Circulation: Cardiovascular Imaging · 2024
DOI: 10.1161/circimaging.123.016276 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation: Cardiovascular Imaging, 2024. Verfasst von Doron Aronson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Cardiology (D.A., H.S., D.P., D.M., J.L.), Rambam Health Care Campus, Haifa, Israel. Hauptthemen laut MEDLINE: Atrial Function, Left, Diastole, Ventricular Dysfunction, Left, Ventricular Function, Left. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Quantification of left atrial (LA) conduit function and its contribution to left ventricular (LV) filling is challenging because it requires simultaneous measurements of both LA and LV volumes. The functional relationship between LA conduit function and the severity of diastolic dysfunction remains controversial. We studied the role of LA conduit function in maintaining LV filling in advanced diastolic dysfunction. METHODS: We performed volumetric and flow analyses of LA function across the spectrum of LV diastolic dysfunction, derived from a set of consecutive patients undergoing multiphasic cardiac computed tomography scanning (n=489). From LA and LV time-volume curves, we calculated 3 volumetric components: (1) early passive emptying volume; (2) late active (booster) volume; and (3) conduit volume. Results were prospectively validated on a group of patients with severe aortic stenosis (n=110). RESULTS: The early passive filling progressively decreased with worsening diastolic function ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Departments of Cardiology (D.A., H.S., D.P., D.M., J.L.), Rambam Health Care Campus, Haifa, Israel.
- Faculty of Medicine (D.A., S.A., D.M., J.L.), Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
- Medical Imaging (S.A.), Rambam Health Care Campus, Haifa, Israel.
- BioMedical Engineering (I.M.), Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
ORCID-Profile: Doron Aronson, Diab Mutlak, Jonathan Lessick
Zitieren
APA
Aronson, D., Sliman, H., Abadi, S., Maiorov, I., Perlow, D., Mutlak, D., & Lessick, J. (2024). Conduit Flow Compensates for Impaired Left Atrial Passive and Booster Functions in Advanced Diastolic Dysfunction. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.123.016276
Vancouver
Aronson D, Sliman H, Abadi S, Maiorov I, Perlow D, Mutlak D, et al. Conduit Flow Compensates for Impaired Left Atrial Passive and Booster Functions in Advanced Diastolic Dysfunction. Circulation: Cardiovascular Imaging. 2024. doi:10.1161/circimaging.123.016276
BibTeX
@article{Aronson2024,
author = {Aronson, Doron and Sliman, Hend and Abadi, Sobhi and Maiorov, Ida and Perlow, Daniel and Mutlak, Diab and Lessick, Jonathan},
title = {Conduit Flow Compensates for Impaired Left Atrial Passive and Booster Functions in Advanced Diastolic Dysfunction},
journal = {Circulation: Cardiovascular Imaging},
year = {2024},
doi = {10.1161/circimaging.123.016276}
}
EUVIMED