Artificial Intelligence Model Predicts Sudden Cardiac Arrest Manifesting With Pulseless Electric Activity Versus Ventricular Fibrillation
Künstliches-Intelligenz-Modell sagt plötzlichen Herzstillstand mit pulslosem elektrischem Aktivitätsmuster versus Kammerflimmern voraus
Circulation: Arrhythmia and Electrophysiology · 2024-02 · 17 (2)
DOI: 10.1161/circep.123.012338 ↗Auf einen Blick
Ein KI-Modell unterschied bei beobachteten außerklinischen Herzstillständen zwischen PEA-SCA und VF-SCA mit mäßiger Trennschärfe. Die Leistung war in einer externen Kohorte ähnlich.
Fragestellung
Kann ein KI-Modell plötzlichen Herzstillstand mit pulsloser elektrischer Aktivität (PEA-SCA) von VF-SCA unterscheiden?
Methode
Trainings- und Testung eines KI-Modells (Extreme Gradient Boosting) mit demografischen und klinischen Variablen; interne Kohorte und externe Validierung bei von Notarztpersonal beobachteten außerklinischen Herzstillständen.
Ergebnisse
Interne Kohorte: 421 außerklinische, von EMS beobachtete Herzstillstände; AUC 0,68 (95 %-KI 0,61–0,76). Externe Kohorte: 220 Fälle; AUC 0,72 (95 %-KI 0,59–0,84).
Schlussfolgerung der Autor:innen
Das KI-Modell identifizierte neue Merkmale von PEA-SCA, unterschied PEA-SCA von VF-SCA und ließ sich in einer externen Kohorte replizieren.
Kernaussagen
- AUC intern 0,68 (95 %-KI 0,61–0,76)
- AUC extern 0,72 (95 %-KI 0,59–0,84)
- Wichtige Merkmale: Anämie, höheres Alter, höheres Gewicht, Dyspnoe
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2024-02. Verfasst von Lauri Holmstrom und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Artificial Intelligence in Medicine, Department of Medicine (L.H., B.B., D.D., P.J.S., S.S.C.). Hauptthemen laut MEDLINE: Heart Arrest, Cardiopulmonary Resuscitation, Emergency Medical Services, Out-of-Hospital Cardiac Arrest. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS.
Abstract (Originalsprache)
BACKGROUND: There is no specific treatment for sudden cardiac arrest (SCA) manifesting as pulseless electric activity (PEA) and survival rates are low; unlike ventricular fibrillation (VF), which is treatable by defibrillation. Development of novel treatments requires fundamental clinical studies, but access to the true initial rhythm has been a limiting factor. METHODS: Using demographics and detailed clinical variables, we trained and tested an AI model (extreme gradient boosting) to differentiate PEA-SCA versus VF-SCA in a novel setting that provided the true initial rhythm. A subgroup of SCAs are witnessed by emergency medical services personnel, and because the response time is zero, the true SCA initial rhythm is recorded. The internal cohort consisted of 421 emergency medical services-witnessed out-of-hospital SCAs with PEA or VF as the initial rhythm in the Portland, Oregon metropolitan area. External validation was performed in 220 emergency medical services-witnessed SCAs from Ventura, CA. RESULTS: In the internal cohort, the artificial intelligence model achieved an area under the receiver operating characteristic curve of 0.68 (95% CI, 0.61–0.76). Model performance was similar in the external cohort, achieving an area under the receiver operating characteristic curve of 0.72 (95% CI, 0.59–0.84). Anemia, older age, increased weight, and dyspnea as a warning symptom were the most important features of PEA-SCA; younger age, chest pain as a warning symptom and established coronary artery disease were important features associated with VF. CONCLUSIONS: The artificial intelligence model identified novel features of PEA-SCA, differentiated from VF-SCA and was successfully replicated in an external cohort. These findings enhance the mechanistic understanding of PEA-SCA with potential implications for developing novel management strategies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Artificial Intelligence in Medicine, Department of Medicine (L.H., B.B., D.D., P.J.S., S.S.C.).
- Center for Cardiac Arrest Prevention, Department of Cardiology, Smidt Heart Institute, Cedars-Sinai Health System, Los Angeles (L.H., H.C., H.A., H.N.P., A.S., A.U.-E., K.R., S.S.C.).
- Ventura County Health Care Agency, Ventura, CA (A.S.).
- Department of Emergency Medicine, Oregon Health and Science University, Portland, OR (J.J.).
ORCID-Profile: Lauri Holmstrom, Bryan Bednarski, Harpriya Chugh, Habiba Aziz, Audrey Uy-Evanado, Damini Dey, Angelo Salvucci, Jonathan Jui, Kyndaron Reinier, Piotr J Slomka, Sumeet S Chugh
Förderung
- NHLBI NIH HHS
Zitieren
APA
Holmstrom, L., Bednarski, B., Chugh, H., Aziz, H., Pham, H. N., Sargsyan, A., Uy-Evanado, A., Dey, D., Salvucci, A., Jui, J., Reinier, K., Slomka, P. J., & Chugh, S. S. (2024). Artificial Intelligence Model Predicts Sudden Cardiac Arrest Manifesting With Pulseless Electric Activity Versus Ventricular Fibrillation. Circulation: Arrhythmia and Electrophysiology, 17(2). https://doi.org/10.1161/circep.123.012338
Vancouver
Holmstrom L, Bednarski B, Chugh H, Aziz H, Pham HN, Sargsyan A, et al. Artificial Intelligence Model Predicts Sudden Cardiac Arrest Manifesting With Pulseless Electric Activity Versus Ventricular Fibrillation. Circulation: Arrhythmia and Electrophysiology. 2024;17(2). doi:10.1161/circep.123.012338
BibTeX
@article{Holmstrom2024,
author = {Holmstrom, Lauri and Bednarski, Bryan and Chugh, Harpriya and Aziz, Habiba and Pham, Hoang Nhat and Sargsyan, Arayik and Uy-Evanado, Audrey and Dey, Damini and Salvucci, Angelo and Jui, Jonathan and Reinier, Kyndaron and Slomka, Piotr J and Chugh, Sumeet S},
title = {Artificial Intelligence Model Predicts Sudden Cardiac Arrest Manifesting With Pulseless Electric Activity Versus Ventricular Fibrillation},
journal = {Circulation: Arrhythmia and Electrophysiology},
year = {2024},
volume = {17},
number = {2},
doi = {10.1161/circep.123.012338}
}