Background

Coronary artery disease (CAD) remains a leading cause of morbidity and mortality worldwide. Flurpiridaz F-18 positron emission tomography (PET) myocardial perfusion imaging has emerged as a promising non-invasive modality for CAD detection. This systematic review and meta-analysis evaluated the diagnostic accuracy of Flurpiridaz F-18 PET compared with conventional single-photon emission computed tomography (SPECT).

Methods

A systematic review of prospective phase II and III clinical trials was conducted to assess the diagnostic performance of Flurpiridaz F-18 PET for CAD detection using invasive coronary angiography (ICA) with ≥50% luminal stenosis as the reference standard. Adults with suspected or known CAD undergoing PET and/or SPECT myocardial perfusion imaging were included. Primary outcomes were sensitivity and specificity. Secondary outcomes included diagnostic odds ratio (DOR), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and summary receiver operating characteristic (SROC) performance.

Results

Three multicenter prospective studies comprising 1,502 patients were included. The pooled sensitivity of Flurpiridaz F-18 PET was 0.762 (95% CI: 0.695-0.819) compared with 0.617 (95% CI: 0.518-0.707) for SPECT. The pooled relative sensitivity ratio was 1.25 (95% CI: 1.13-1.39; prediction interval: 1.07-1.46), demonstrating significantly greater sensitivity for PET (z=4.22, p

Zitieren

APA

Tariq, B., Ghaleb, A., Rizwan, M., Mustafa, M., Hafeez, A. S., Abbasi, S. U. A. M., sharif, I., Haq, M. A. U., Ayalew, B. D., Mubarika, M., Ali, Z., & Komel, A. (2026). Abstract 9435: Diagnostic Accuracy of Flurpiridaz F-18 Positron Emission Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease: A Systematic Review and Meta-Analysis. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.9435

Vancouver

Tariq B, Ghaleb A, Rizwan M, Mustafa M, Hafeez AS, Abbasi SUAM, et al. Abstract 9435: Diagnostic Accuracy of Flurpiridaz F-18 Positron Emission Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease: A Systematic Review and Meta-Analysis. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.9435

BibTeX
@article{Tariq2026,
  author = {Tariq, Bisma and Ghaleb, Abdulrahman and Rizwan, Maheen and Mustafa, Mariam and Hafeez, Ali Shan and Abbasi, Sabahat Ul Ain Munir and sharif, iman and Haq, Muhammad Areeb Ul and Ayalew, Biruk Demisse and Mubarika, Moosa and Ali, Zain and Komel, Aqsa},
  title = {Abstract 9435: Diagnostic Accuracy of Flurpiridaz F-18 Positron Emission Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease: A Systematic Review and Meta-Analysis},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.9435}
}
Kostenlos starten →