Purpose
Maximal aortic diameter guides clinical care of thoracic aortic disease, yet diameter is a 1D measure of a 3D structure, and prior work has shown poor correlation between diameter and future growth. Virtual Normal (VN) is an emerging statistical method that quantifies an individual's aortic size in 3D relative to a normative reference population (z-score), estimating expected diameter and normal variation at every aortic surface point. We evaluated whether 3D personalized aortic size by VN z-score improves correlation with aortic growth rate compared to baseline diameter. Research Questions/Hypothesis: We hypothesized that baseline 3D personalized aortic size measured by VN z-score would correlate with and predict VDM-derived ascending aortic growth rate Methods: In this retrospective cohort study, we included patients with serial chest CT angiography. Aortic growth rate (mm/yr) was computed from serial CTAs using Vascular Deformation Mapping (VDM), a state-of-the-art method for accurate 3D aortic growth quantification. Baseline VN scores were derived from the index CTA, yielding two outputs: a population-based z-score and a personalized z-score adjusted for age, sex, and body surface area. Spearman correlation assessed the association between baseline VN score and annualized growth rate. Linear regression evaluated VN score as a predictor of growth rate. Multivariate regression then assessed VN score as an independent predictor after adjustment for baseline diameter, interval duration, and clinical risk factors.
Results
374 patients were included (mean age 60.8 years [SD 1.4], 76.2% male, mean baseline diameter 42.7mm [SD 3.75]; mean VDM interval 4.73 years [SD 2.57]). Personalized VN z-score was not associated with ascending aortic growth rate (r = –0.028, p = 0.584). For linear regression, neither personalized VN z-score (β = 0.004; 95% CI –0.017 to 0.025; p = 0.723) nor baseline diameter (β = –0.001; 95% CI –0.007 to 0.005; p = 0.820) predicted growth rate. On multivariate analysis (n = 366), VN z-score remained a non-significant predictor of ascending aortic growth rate after adjustment for baseline diameter, interval duration, and clinical risk factors (hypertension, diabetes, tobacco use, bicuspid aortic valve, aortic insufficiency, aortic stenosis, and family history of aortic disease).
Conclusion
The lack of correlation between aortic size and growth rate, despite 3D analyses of each, suggests that size-based metrics are poor surrogates of the biological processes driving aortic progression and life-threatening complications.
Zitieren
APA
Murad, B., Karnam, Y., Jorge, C. A. C., Neto, I. Q. C., Spahlinger, G., George, G., & Burris, N. S. (2026). Abstract 9031: Virtual Normal Ascending Aortic Diameter Mapping Does Not Improve Prediction of Aortic Growth Rate Over Diameter. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.9031
Vancouver
Murad B, Karnam Y, Jorge CAC, Neto IQC, Spahlinger G, George G, et al. Abstract 9031: Virtual Normal Ascending Aortic Diameter Mapping Does Not Improve Prediction of Aortic Growth Rate Over Diameter. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.9031
BibTeX
@article{Murad2026,
author = {Murad, Bruno and Karnam, Yogesh and Jorge, Carlos Alberto Campello and Neto, Ivo Queiroz Costa and Spahlinger, Greg and George, Grace and Burris, Nicholas S},
title = {Abstract 9031: Virtual Normal Ascending Aortic Diameter Mapping Does Not Improve Prediction of Aortic Growth Rate Over Diameter},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.9031}
}
EUVIMED