Abstract 8515: Allograft Valves Harvesting and Preservation Technique for Enhanced Performance
Circulation · 02.11.2026 · 154 (Suppl_1)
DOI: 10.1161/circ.154.suppl_1.8515 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Congrui Wang und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Limited availability of allograft valves remains a major obstacle to their widespread clinical application. Harvesting valves from heart transplant recipients may represent an alternative source of allografts. We aimed to evaluate a simplified harvesting and cryopreservation strategy and investigate the clinical outcomes of recipient-derived allograft valves used for pulmonary valve replacement (PVR).
Methods
Allograft valves were harvested from heart transplant recipients at our institution between October 2007 and October 2022 using a modified preservation protocol involving sequential storage at 4°C, –80°C, and –196°C. Sixty patients undergoing PVR during or after tetralogy of Fallot repair received these allograft valves. Clinical follow-up data were collected retrospectively. The primary endpoint was adverse clinical outcome (ACO), defined as a composite of all-cause mortality, endocarditis, significant right ventricular outflow tract obstruction, or moderate-to-severe pulmonary regurgitation. Kaplan-Meier analysis and multivariable logistic regression were performed to evaluate outcomes and identify predictors of ACO.
Results
The median age of recipients was 5.1 years (IQR 1.5-12.1), and median follow-up was 2.6 years (IQR 1.0-6.9). Freedom from all-cause mortality was 94.0%, 89.5%, and 89.5% at 5, 10, and 15 years, respectively. Freedom from ACO was 64.9%, 53.4%, and 31.7% at 5, 10, and 15 years, respectively. No cases of endocarditis were observed during follow-up. Multivariable analysis identified bicuspidized allograft valves (OR 75.09, 95% CI 10.10-558.20, P
Zitieren
APA
Wang, C., & Shu, C. (2026). Abstract 8515: Allograft Valves Harvesting and Preservation Technique for Enhanced Performance. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.8515
Vancouver
Wang C, Shu C. Abstract 8515: Allograft Valves Harvesting and Preservation Technique for Enhanced Performance. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.8515
BibTeX
@article{Wang2026,
author = {Wang, Congrui and Shu, Chang},
title = {Abstract 8515: Allograft Valves Harvesting and Preservation Technique for Enhanced Performance},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.8515}
}
EUVIMED