Abstract 8304: Localizing Accessory Pathways Using Diffusion Based Modeling

Marcus Talke, Jonah Majumder, Soo Young Park, Edward J Ciaccio, Hirad Yarmohammadi, Jessica Hennessey, Geoffrey Rubin, Angelo B Biviano, Hasan Garan, Ellie Coromilas, Elaine Y Wan, Raghd Ahmed und 4 weitere

Circulation · 02.11.2026 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.8304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Marcus Talke und 15 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Catheter ablation of accessory pathways (APs) often relies on visual interpretation of local activation time (LAT) maps, with limited quantitative tools to localize APs. Building on our prior work using LAT-derived features, we introduce a novel diffusion-based method to model excitation spread for AP localization. Research Question: Can a diffusion-based feature, called excitation spread, localize APs from high-density LAT maps, using successful ablation sites as the reference standard?

Methods

High-density LAT maps from 15 patients undergoing AP ablation were retrospectively analyzed. Conduction speed (CS) maps were derived from LAT gradients; the annular line of block was manually identified as a low-CS line (non-zero due to LAT interpolation artifact). Excitation spread was computed at each mesh node by simulating a diffusion process weighted by conduction velocity, capturing the extent of activation propagation from each site. Excitation spread was then evaluated along the distal chamber with respect to the annular line. Ablation lesions were projected onto the line, and accuracy was defined as the proportion of lesions within 10 mm of the excitation spread peak.

Results

The median proportion of ablation lesions aligned with the peak of excitation spread was 100 % (IQR 81.3-100%). Ablation lesions lay a median 4.2 mm (IQR 3.1-4.7 mm) from the annular line of block, with a median spread along the line of 11.6 mm (IQR 8.6-14.7 mm). Figure 1 shows an example of an excitation spread map, that highlights a narrow channel AP across the tricuspid annulus.

Conclusions

We developed a diffusion-based modeling approach to localize APs, with potential to support ablation planning.

Zitieren

APA

Talke, M., Majumder, J., Park, S. Y., Ciaccio, E. J., Yarmohammadi, H., Hennessey, J., Rubin, G., Biviano, A. B., Garan, H., Coromilas, E., Wan, E. Y., Ahmed, R., Liger, A. B., Arpi, M., Hendon, C. P., & Saluja, D. S. (2026). Abstract 8304: Localizing Accessory Pathways Using Diffusion Based Modeling. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.8304

Vancouver

Talke M, Majumder J, Park SY, Ciaccio EJ, Yarmohammadi H, Hennessey J, et al. Abstract 8304: Localizing Accessory Pathways Using Diffusion Based Modeling. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.8304

BibTeX
@article{Talke2026,
  author = {Talke, Marcus and Majumder, Jonah and Park, Soo Young and Ciaccio, Edward J and Yarmohammadi, Hirad and Hennessey, Jessica and Rubin, Geoffrey and Biviano, Angelo B and Garan, Hasan and Coromilas, Ellie and Wan, Elaine Y and Ahmed, Raghd and Liger, Ashley B and Arpi, Mark and Hendon, Christine P and Saluja, Deepak S},
  title = {Abstract 8304: Localizing Accessory Pathways Using Diffusion Based Modeling},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.8304}
}
Kostenlos starten →