Abstract (Originalsprache)

Objectives

To determine the impact of ascending aortic graft replacement on left ventricular (LV) performance using multiparametric cardiovascular magnetic resonance (CMR) imaging.

Background

Prosthetic ascending aortic grafts prevent proximal, life-threatening dissection in patients with genetic thoracic aortic aneurysms and related conditions (gTAA) but are stiffer than native tissue and would be expected to increase LV afterload. However, impact of graft-induced alterations on comprehensive LV performance using CMR has yet to be studied. Methods: gTAA patients undergoing proximal ascending aortic graft replacement prospectively underwent tailored multiparametric CMR pre- and post-operatively, including aortic (4D) flow, geometric (MRA), tissue characterization (LGE), and functional (cine) imaging. LV function was assessed volumetrically and via global longitudinal strain (GLS). Impaired post-operative LV function was defined as ≥10% reduction in LV-GLS.

Results

50 gTAA patients (66% heritable, 34% bicuspid) underwent CMR pre- (0.2±0.5 months) and post- (4.1±3.1 months) aortic graft placement. Surgery yielded substantial changes in aortic geometry accompanied by altered tissue stiffness and flow; decreased ascending aortic size paralleled a ~3-fold increase in stiffness within graft-replaced regions based on reduced strain (3.9±1.8 vs. 1.2±1.1%) and distensibility (1.7±0.8 vs. 0.5±0.5 10 -3 mmHg -1 ), and increased wall shear stress (0.5±0.2 vs. 0.7±0.4Pa; all p

Zitieren

APA

Reza, M., Narula, N., Ianniruberto, I., Calle, P. V., Gaudino, M. F., Astori, D., Kim, J., Manowitz, E., Naami, E., Axman, R., Roman, M. J., Devereux, R. B., Trinder, K., Humphrey, J. D., Wang, Y., Lau, C., redaelli, A., Girardi, L. N., & Weinsaft, J. W. (2026). Abstract 7807: Ascending Aortic Graft Replacement Alters Left Ventricular Performance: Novel Insights Enabled by Multiparametric 4D Flow CMR. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.7807

Vancouver

Reza M, Narula N, Ianniruberto I, Calle PV, Gaudino MF, Astori D, et al. Abstract 7807: Ascending Aortic Graft Replacement Alters Left Ventricular Performance: Novel Insights Enabled by Multiparametric 4D Flow CMR. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.7807

BibTeX
@article{Reza2026,
  author = {Reza, Mahniz and Narula, Nupoor and Ianniruberto, Ione and Calle, Pablo Villar and Gaudino, Mario F and Astori, Davide and Kim, Jiwon and Manowitz, Elizabeth and Naami, Edmund and Axman, Rachel and Roman, Mary J and Devereux, Richard B and Trinder, Kaitlyn and Humphrey, Jay D and Wang, Yadong and Lau, Christopher and redaelli, alberto and Girardi, Leonard N and Weinsaft, Jonathan W},
  title = {Abstract 7807: Ascending Aortic Graft Replacement Alters Left Ventricular Performance: Novel Insights Enabled by Multiparametric 4D Flow CMR},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.7807}
}
Kostenlos starten →