Abstract 7579: Patient-Reported Outcomes Improve After Pulmonary Valve Replacement in Patients with Repaired Tetralogy of Fallot
Circulation · 02.11.2026 · 154 (Suppl_1)
DOI: 10.1161/circ.154.suppl_1.7579 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von KOHSAKU GOTO und 23 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Although the importance of patient-reported outcomes (PROs) is increasingly being recognized in acquired heart disease, there is a paucity of data pertaining to PROs in congenital heart disease (CHD), particularly after cardiac intervention. We therefore examined PROs in patients with repaired tetralogy of Fallot (rTOF) and pulmonary valve replacement (PVR). We aimed to explore PRO changes post PVR and identify factors associated with PRO improvement post PVR.
Methods
This was a substudy within the larger prospective, multi-center, longitudinal study of adolescents and adults (≥12 years old) with rTOF and significant pulmonary regurgitation (≥ moderate) entitled CORRELATE (Comprehensive Outcomes Registry Late After Tetralogy of Fallot Repair). We included patients with PVR following study enrollment and pre/post-PVR PROs which characterized quality of life (QOL) and health status (HS). There were 4 QOL surveys (PedsQL, PCQLI, QOL-LAS and SWLS) and 5 HS surveys (SF-12, EQ-5D, self-reported NYHA functional class, SAS and CHD-TAAQOL) ( Tables 1 and 2 ). Minimally clinically important differences (MCID) for each survey tool with continuous variables were defined based on published literature. A change of ≥1 class on the self-reported NYHA was considered a significant improvement. PRO responsivity post PVR was defined as improvement in ≥50% of surveys completed (achievement of MCID and/or NYHA improvement).
Results
Of 720 rTOF patients in the CORRELATE study, 145 patients had a PVR following study enrollment with pre/post-PVR PROs (mean age at study entry 28.5±13.3 years, 43% female). Following PVR, the only QOL measure that demonstrated improvement was the social functioning subscale of the PedsQL (83.0→88.1 [p=0.049]) ( Table 1 ). Of the HS measures, improvement post-PVR was noted in the SF-12 physical component score, EQ-5D visual analogue scale (EQ-5D VAS) and CHD-TAAQOL (48.4→50.8 [p=0.011], 75.3→79.5 [p=0.004] and 82.8→88.9 [p
Zitieren
APA
GOTO, K., Tomlinson, G., Raptis, S., Dahdah, N., Dallaire, F., Drolet, C., Grewal, J., Friesen, C. L. H., Karur, G. R., Keir, M., Kovacs, A., Leonardi, B., Nadeem, S., Ng, M., Shah, A., Tham, E. B., Therrien, J., Bruaene, A. V. D., Muhll, I. V., …, & Wald, R. M. (2026). Abstract 7579: Patient-Reported Outcomes Improve After Pulmonary Valve Replacement in Patients with Repaired Tetralogy of Fallot. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.7579
Vancouver
GOTO K, Tomlinson G, Raptis S, Dahdah N, Dallaire F, Drolet C, et al. Abstract 7579: Patient-Reported Outcomes Improve After Pulmonary Valve Replacement in Patients with Repaired Tetralogy of Fallot. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.7579
BibTeX
@article{GOTO2026,
author = {GOTO, KOHSAKU and Tomlinson, George and Raptis, Stavroula and Dahdah, Nagib and Dallaire, Frederic and Drolet, Christian and Grewal, Jasmine and Friesen, Camille L Hancock and Karur, Gauri Rani and Keir, Michelle and Kovacs, Adrienne and Leonardi, Benedetta and Nadeem, Syed and Ng, Ming-Yen and Shah, Ashish and Tham, Edythe B and Therrien, Judith and Bruaene, Alexander Van De and Muhll, Isabelle Vonder and Warren, Andrew and Yamamura, Kenichiro and Khairy, Paul and Silversides, Candice and Wald, Rachel M},
title = {Abstract 7579: Patient-Reported Outcomes Improve After Pulmonary Valve Replacement in Patients with Repaired Tetralogy of Fallot},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.7579}
}
EUVIMED