EUVIMEDEUVIMED entdecken
Crossref

Abstract 7488: Atrial Leadless Pacemaker Implantation via Femoral Venous Approach in Extracardiac Fontan Circulation

Riya Janardhan, Daniel Cortez

Circulation · 02.11.2026 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.7488 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Riya Janardhan und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Patients with Fontan circulation frequently develop sinus node dysfunction requiring pacing, but conventional options remain limited. Transvenous systems are often precluded by altered venous pathways and thromboembolic risk, while epicardial systems require repeat surgery and carry higher long-term complication rates. Leadless pacing offers a minimally invasive alternative; however, atrial implantation in extracardiac Fontan anatomy remains technically challenging. Case Presentation: A 24-year-old female with complex congenital heart disease status post extracardiac Fontan presented with symptomatic chronotropic incompetence and reduced exercise capacity (VO 2 max 15.3 mL/kg/min, 36% predicted). Her relevant history included a double outlet right ventricle, ventricular inversion, pulmonary stenosis, a hypoplastic left ventricle with a history of palliation, Glenn, and eventual extra-cardiac fenestrated Fontan, s/p fenestration closure. Her echocardiogram demonstrated normal systemic ventricular function without atrioventricular valvular regurgitation and with laminar Glenn and Fontan flow. The baseline electrocardiogram showed a lower atrial rhythm. Management: To avoid repeat thoracotomy, a transvenous atrial leadless pacing strategy was pursued. Hemodynamics demonstrated stable Fontan physiology. Three-dimensional electroanatomic mapping identified a discrete high-voltage target at the inferior vena cava-atrial junction, below the Fontan conduit. A leadless atrial pacemaker was successfully implanted via femoral venous access without the need for trans-baffle puncture, alternative access (e.g., carotid), or surgical exposure. Imaging confirmed secure device position with preserved laminar Fontan flow and no obstruction. At 1-month follow-up, device parameters remained stable with appropriate atrial sensing and pacing.

Conclusion

This case demonstrates a streamlined, fully percutaneous femoral approach for implantation of a leadless atrial pacemaker in patients with an extracardiac Fontan circulation. By avoiding complex access strategies and repeat surgical interventions while maintaining physiologic atrial contribution to ventricular filling, this technique offers a practical, less invasive alternative for pacing in this high-risk population. Further investigation is needed to define long-term outcomes, durability, and optimal patient selection.

Zitieren

APA

Janardhan, R., & Cortez, D. (2026). Abstract 7488: Atrial Leadless Pacemaker Implantation via Femoral Venous Approach in Extracardiac Fontan Circulation. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.7488

Vancouver

Janardhan R, Cortez D. Abstract 7488: Atrial Leadless Pacemaker Implantation via Femoral Venous Approach in Extracardiac Fontan Circulation. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.7488

BibTeX
@article{Janardhan2026,
  author = {Janardhan, Riya and Cortez, Daniel},
  title = {Abstract 7488: Atrial Leadless Pacemaker Implantation via Femoral Venous Approach in Extracardiac Fontan Circulation},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.7488}
}
Kostenlos starten →