Abstract 6032: Artificial Intelligence ECG Accurately Predicts Occlusive Myocardial Infarction Following Out-of-Hospital Cardiac Arrest with Shockable Rhythm
Abstract 6032: Künstliche-Intelligenz-EKG sagt okklusiven Myokardinfarkt nach außerklinischem Herzstillstand mit schockbarem Rhythmus genau voraus
Circulation · 02.11.2026 · 154 (Suppl_1)
DOI: 10.1161/circ.154.suppl_1.6032 ↗Auf einen Blick
Bei 295 OHCA-Fällen sagte ein AI-EKG einen okklusiven Myokardinfarkt besser voraus als kardiologisch beurteilte STEMI-Kriterien. Die Diskrimination war höher, die Spezifität aber geringer.
Fragestellung
Kann AI-ECG einen okklusiven Myokardinfarkt nach OHCA mit schockbarem Rhythmus ähnlich genau erkennen wie kardiologisch beurteilte STEMI-Kriterien?
Methode
Retrospektive Kohortenstudie an der University of Washington bei OHCA mit initial schockbarem Rhythmus und Koronarangiographie 2013-2023; Analyse des ersten stationären EKGs mit AI-Modell; Vergleich per DeLong-Test.
Ergebnisse
295 OHCA-Fälle, davon 139 mit OMI (47%). AUROC 0,83 (95 %-KI 0,78–0,87) für AI-ECG vs. 0,78 (95 %-KI 0,73–0,82) für STEMI-Kriterien; p=0,047. Sensitivität 70 % vs. 63 %, Spezifität 85 % vs. 93 %, PPV 80 % vs. 89 %, NPV 76 % vs. 74 %.
Schlussfolgerung der Autor:innen
Die AI-ECG-Analyse nach OHCA sagt OMI mit guter Diskrimination und vergleichbarer Vorhersagekraft wie kardiologisch beurteilte STEMI-Kriterien voraus. Sie erkannte 40 % der OMI-Fälle, die nicht die Leitlinienindikation für eine dringliche Angiographie erfüllten.
Kernaussagen
- OMI bei 139 von 295 OHCA-Fällen (47 %)
- AUROC 0,83 vs. 0,78; p=0,047
- AI-ECG erkannte 40 % der von Kardiolog:innen als NSTEMI eingestuften OMI-Fälle
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Albert Feeny und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Out-of-hospital cardiac arrest (OHCA) with an initial shockable rhythm is frequently caused by acute coronary syndrome. Guidelines recommend immediate coronary angiography after OHCA only in the setting of ST-elevation myocardial infarction (STEMI). However, traditional STEMI criteria may have limited sensitivity and specificity for occlusive myocardial infarction (OMI) in the post-OHCA setting. Artificial intelligence (AI) models have shown promise in detecting OMI from ECG, though their utility after OHCA is unknown. Research hypothesis: AI-ECG can detect occlusive myocardial infarction after shockable OHCA with comparable accuracy to cardiologist-assessed STEMI criteria.
Methods
A retrospective cohort study was conducted at University of Washington of patients with OHCA with an initial shockable rhythm who underwent coronary angiogram and had a digital ECG available within 30 days post-arrest (2013-2023). Patients without an ECG prior to angiography were excluded. Coronary angiograms were adjudicated for OMI, defined as thrombotic lesion with abnormal TIMI flow, or an obstructive lesion with normal TIMI flow and a peak troponin ≥70 times the upper limit of normal. Each case was reviewed for STEMI or STEMI-equivalent criteria using all available clinical data leading up to angiography. The first available hospital ECG was analyzed by the AI model to predict presence of OMI. Diagnostic accuracy was assessed using area under the receiver operating characteristic curve (AUROC) and compared using the DeLong test. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were also calculated.
Results
Of 295 OHCA cases undergoing angiography, OMI was present in 139 (47%). Compared to cardiologist-assessed STEMI criteria, AI-ECG showed superior discrimination for OMI (AUROC 0.83 [95% CI: 0.78-0.87] vs. 0.78 [95% CI: 0.73-0.82], p=0.047), higher sensitivity (70% vs. 63%), lower specificity (85% vs. 93%), lower PPV (80% vs. 89%) and higher NPV (76% vs. 74%). There were 52 OMI cases labeled by cardiologists as NSTEMI, of which the AI ECG model correctly predicted OMI in 21 (40%) cases. There were 42 OMI cases missed by the AI ECG model, of which cardiologists labeled STEMI or STEMI-equivalent in 11 (26%) cases.
Conclusion
AI-ECG analysis after OHCA accurately predicts OMI with superior discrimination and comparable predictive accuracy compared to cardiologist-assessed STEMI criteria. AI-ECG identified 40% of individuals with OMI not meeting guideline-indication for urgent angiography after OHCA.
Zitieren
APA
Feeny, A., Magoon, M. J., Boyle, P. M., Nakamura, K., & Chatterjee, N. (2026). Abstract 6032: Artificial Intelligence ECG Accurately Predicts Occlusive Myocardial Infarction Following Out-of-Hospital Cardiac Arrest with Shockable Rhythm. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.6032
Vancouver
Feeny A, Magoon MJ, Boyle PM, Nakamura K, Chatterjee N. Abstract 6032: Artificial Intelligence ECG Accurately Predicts Occlusive Myocardial Infarction Following Out-of-Hospital Cardiac Arrest with Shockable Rhythm. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.6032
BibTeX
@article{Feeny2026,
author = {Feeny, Albert and Magoon, Matthew J and Boyle, Patrick M and Nakamura, Kenta and Chatterjee, Neal},
title = {Abstract 6032: Artificial Intelligence ECG Accurately Predicts Occlusive Myocardial Infarction Following Out-of-Hospital Cardiac Arrest with Shockable Rhythm},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.6032}
}
EUVIMED