EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Abstract 5159: Comparative Effectiveness and Safety of Myval versus Evolut Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis

Fatima Sohail, Mohammad Ismail Asim, Ahmed E Mohamed, Muzainah Tabassum, Junaid Razzak, Muhammad Talha Usman, Shan e Ali Shoukat, Mezhgan Kiwan, Basit Ali, Taha Alam, Zainab Nouman, Ehsanullah Alokozay

Circulation · 02.11.2026 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.5159 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Fatima Sohail und 11 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Background: The Myval balloon-expandable transcatheter heart valve (THV) has emerged as an alternative to established platforms; however, comparative evidence with the Evolut self-expanding THV remains limited, particularly regarding procedural performance and conduction outcomes. Research Questions/Hypothesis: We evaluated comparative clinical and procedural outcomes between Myval and Evolut THVs in patients undergoing transcatheter aortic valve implantation (TAVI). Methods/Approach: A systematic search of PubMed, EMBASE, Scopus, and the Cochrane Library was conducted for studies published through March 2026. Eligible studies were observational comparative cohorts directly comparing Myval and Evolut THVs. Quality was appraised using the Newcastle-Ottawa Scale and certainty of evidence using the GRADE approach. Primary outcomes included all-cause mortality, permanent pacemaker implantation (PPI), and transvalvular aortic regurgitation. Secondary outcomes included technical success and vascular complications. Pooled risk ratios (RRs) with 95% confidence intervals (CIs) were calculated using a random-effects model. Heterogeneity was assessed using I 2 statistics, and publication bias was evaluated using funnel plots. Results/Data: Six observational studies (n=1332) were included. Myval was associated with a significantly lower PPI risk (RR 0.56, 95% CI 0.37-0.84; p=0.005; I 2 =0%) and comparable 30-day mortality (RR 0.83, 95% CI 0.31-2.23; p=0.72; I 2 =0%). No significant difference was observed in transvalvular aortic regurgitation (RR 0.25, 95% CI 0.03-1.97; p=0.19; I 2 =45%); however, sensitivity analysis excluding one heterogeneity-driving study demonstrated a significant reduction favoring Myval (RR 0.10, 95% CI 0.02-0.56; p=0.008; I 2 =0%). Myval demonstrated higher technical success (RR 1.06, 95% CI 1.03-1.10; p

Zitieren

APA

Sohail, F., Asim, M. I., Mohamed, A. E., Tabassum, M., Razzak, J., Usman, M. T., Shoukat, S. E. A., Kiwan, M., Ali, B., Alam, T., Nouman, Z., & Alokozay, E. (2026). Abstract 5159: Comparative Effectiveness and Safety of Myval versus Evolut Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.5159

Vancouver

Sohail F, Asim MI, Mohamed AE, Tabassum M, Razzak J, Usman MT, et al. Abstract 5159: Comparative Effectiveness and Safety of Myval versus Evolut Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.5159

BibTeX
@article{Sohail2026,
  author = {Sohail, Fatima and Asim, Mohammad Ismail and Mohamed, Ahmed E and Tabassum, Muzainah and Razzak, Junaid and Usman, Muhammad Talha and Shoukat, Shan e Ali and Kiwan, Mezhgan and Ali, Basit and Alam, Taha and Nouman, Zainab and Alokozay, Ehsanullah},
  title = {Abstract 5159: Comparative Effectiveness and Safety of Myval versus Evolut Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.5159}
}
Kostenlos starten →