Abstract 18282: Leadless Pacemaker Implantation in Solid Organ Transplant Recipients: Comparative Experience with Micra and Aveir Platforms
Circulation · 02.11.2026 · 154 (Suppl_1)
DOI: 10.1161/circ.154.suppl_1.18282 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Amal Youssef und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Solid organ transplant recipients are vulnerable to cardiac implantable electronic device complications because of immunosuppression, dialysis dependence, recurrent infection, and comorbidity. Leadless pacemakers eliminate transvenous leads and generator pockets, but transplant-specific data comparing Micra and Aveir platforms are limited.
Objective
To describe clinical characteristics, procedural outcomes, infectious complications, device-related events, and mortality among solid organ transplant recipients undergoing Micra or Aveir leadless pacemaker implantation.
Methods
Retrospective cohort study of 52 adult solid organ transplant recipients who underwent leadless pacemaker implantation across Mayo Clinic sites and were categorized by platform. Implantation of a Micra tined-fixation ventricular leadless pacemaker or an Aveir helix-fixation leadless pacemaker, including atrial, ventricular, and dual-chamber configurations. Procedural success, intraprocedural complications, bacteremia before and after implantation, pocket infection, hematoma, device-related issues, pacing-induced cardiomyopathy, pericardial effusion, device upgrade, and all-cause mortality.
Results
Among 52 solid organ transplant recipients, median age at implantation was 70.4 years (IQR, 62-78), and 29 patients (56%) were male. Micra was implanted in 39 patients (75%) and Aveir in 13 patients (25%). Median follow-up was 1.11 years (IQR, 0.58-2.42). Critical illness at implantation was present in 31 patients (60%), and 32 patients (6%) were receiving dialysis. Transplanted organs included heart (13, 25%), lung (6, 11.5%), kidney (33, 6.5%), and liver (8, 15.4%) with 26.9% having multiple organ transplants. Procedural success was achieved in 51 patients (98.1%), and no intraprocedural complications were documented. Bacteremia after implantation occurred in 5 patients (9.6%), all in the Micra group. No device dislodgement, or pacemaker malfunction was observed. Right ventricular pacing-induced cardiomyopathy was noted in 2 patients (4%) and upgrade to an ICD or transvenous pacemaker in 4 (7.7%). During follow-up, 19 patients died (36.5%) due to non-device related causes.
Conclusions
In solid organ transplant recipients, leadless pacemaker implantation was feasible and associated with high procedural success despite substantial comorbidity and infection vulnerability. Micra was the predominant platform, while Aveir expanded leadless pacing to atrial and dual-chamber configurations. Larger studies are needed to define platform-specific outcomes.
Zitieren
APA
Youssef, A., Etchegoyen, C. V., Elnouty, M., Masry, H. E., & Sardana, M. (2026). Abstract 18282: Leadless Pacemaker Implantation in Solid Organ Transplant Recipients: Comparative Experience with Micra and Aveir Platforms. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.18282
Vancouver
Youssef A, Etchegoyen CV, Elnouty M, Masry HE, Sardana M. Abstract 18282: Leadless Pacemaker Implantation in Solid Organ Transplant Recipients: Comparative Experience with Micra and Aveir Platforms. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.18282
BibTeX
@article{Youssef2026,
author = {Youssef, Amal and Etchegoyen, Cecilia Villa and Elnouty, Mohamad and Masry, Hicham El and Sardana, Mayank},
title = {Abstract 18282: Leadless Pacemaker Implantation in Solid Organ Transplant Recipients: Comparative Experience with Micra and Aveir Platforms},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.18282}
}
EUVIMED