Abstract 17872: Leadless Pacemaker Implantation Following Surgical Tricuspid Valve Replacement: A Case Series
Circulation · 02.11.2026 · 154 (Suppl_1)
DOI: 10.1161/circ.154.suppl_1.17872 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Mohammad Husain und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Surgical tricuspid valve (TV) repair or replacement can be complicated by post-operative bradyarrhythmias requiring permanent pacemaker (PPM) implantation. Traditional transvenous PPMs can worsen TR, interfere with prosthetic valves, or cause structural complications such as leaflet impingement. We present a case series describing successful dual- and single-chamber leadless PPM placement in three patients following TV surgery. Case 1: A 60-year-old man with severe mitral and tricuspid regurgitation underwent mitral valve replacement and TV repair complicated by tachy-brady syndrome and sinus node dysfunction. A dual-chamber leadless pacemaker implantation was performed and the ventricular device was safely passed through the repaired TV with successful deployment and uncomplicated post-operative course. Case 2: A 50-year-old woman with a prior bioprosthetic TV replacement developed complete heart block requiring biventricular PPM implantation, which was complicated by phrenic nerve stimulation. Her BiV system was extracted and dual-chamber leadless PPMs were successfully implanted with no significant tricuspid regurgitation on post-operative echocardiography. Case 3: A 67-year-old woman with severe TR underwent extraction of a dual-chamber ICD due to TV impingement, followed by bioprosthetic TV replacement. Persistent junctional rhythm with hemodynamic compromise necessitated single-chamber leadless PPM implantation.
Conclusion
When placed with meticulous catheter manipulation, leadless systems offer a safe alternative for patients requiring pacing after TV surgery.
Zitieren
APA
Husain, M., Nebu, A., Paulraj, S., & Hadadi, C. (2026). Abstract 17872: Leadless Pacemaker Implantation Following Surgical Tricuspid Valve Replacement: A Case Series. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.17872
Vancouver
Husain M, Nebu A, Paulraj S, Hadadi C. Abstract 17872: Leadless Pacemaker Implantation Following Surgical Tricuspid Valve Replacement: A Case Series. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.17872
BibTeX
@article{Husain2026,
author = {Husain, Mohammad and Nebu, Alexander and Paulraj, Shweta and Hadadi, Cyrus},
title = {Abstract 17872: Leadless Pacemaker Implantation Following Surgical Tricuspid Valve Replacement: A Case Series},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.17872}
}
EUVIMED