Background
Limited interpretability remains a major barrier to clinician trust in AI-ECG models. However, the tradeoff between interpretability and discriminative performance, and the morphologies used by black-box models across distinct cardiac diseases, remain incompletely characterized. Research Questions: What is the discriminative performance of increasingly interpretable ECG representations, and what morphologic features are used by state-of-the-art (SOTA) AI-ECG models for cardiac amyloidosis (CA) and left ventricular systolic dysfunction (LVSD)?
Methods
We studied 2 large, diverse US cohorts used to develop SOTA AI-ECG models: a CA cohort of 132,857 individuals (383,550 ECGs) and an LVSD cohort of 87,501 individuals (241,760 ECGs). For each disease, we compared the full black-box AI-ECG model with increasingly interpretable alternatives: a linear model trained on latent embeddings from a partially interpretable variational autoencoder (VAE), a parsimonious tree-based clinical score using ECG parameters and clinician-labeled features, and previously described ECG features associated with each disease. To examine the morphologic features underlying black-box predictions, we trained a Symbol-Concept Association Network to align model predictions with the VAE latent space and performed latent traversal.
Results
Established ECG features of CA (low voltage, pseudo-infarct pattern, and atrioventricular block) and LVSD (left bundle branch block, left ventricular hypertrophy, and atrial fibrillation) demonstrated modest discrimination, with AUCs of 0.653 (95% CI, 0.579-0.725) and 0.635 (95% CI, 0.616-0.653), respectively. Newly derived parsimonious clinical scores improved discrimination, incorporating PR interval, QRS axis, and QT interval for CA (AUC 0.815 [95% CI, 0.767-0.858]) and T-wave axis and QRS duration for LVSD (AUC 0.831 [95% CI, 0.817-0.844]). The partially interpretable VAE model further improved discrimination, with AUCs of 0.880 (95% CI, 0.836-0.920) for CA and 0.897 (95% CI, 0.885-0.908) for LVSD, approaching the performance of the full black-box models (AUC 0.897 [95% CI 0.850-0.938] and 0.914 [95% CI 0.905-0.923], respectively). Latent traversal revealed that high risk for CA was associated with P-wave abnormalities, axis deviations, and QT prolongation, whereas high risk for LVSD was characterized by T-wave axis changes with relative preservation of the QT interval and P-wave morphology.
Conclusion
A partially interpretable VAE AI-ECG model had only a modest reduction in discrimination compared to a black-box model, whereas simpler parameter- and feature-based scores offered point-of-care usability at the expense of lower performance. We revealed overlapping but disease-distinct ECG morphologies underlying AI-ECG predictions, supporting more transparent and clinically usable models.
Zitieren
APA
Batinica, B., Dhingra, L. S., Choi, R., Oikonomou, E. K., & Khera, R. (2026). Abstract 17644: What Do AI-ECG Models See? Interpretable Representations and Morphologic Signatures Across Two Cardiac Diseases. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.17644
Vancouver
Batinica B, Dhingra LS, Choi R, Oikonomou EK, Khera R. Abstract 17644: What Do AI-ECG Models See? Interpretable Representations and Morphologic Signatures Across Two Cardiac Diseases. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.17644
BibTeX
@article{Batinica2026,
author = {Batinica, Bruno and Dhingra, Lovedeep S and Choi, Ryan and Oikonomou, Evangelos K. and Khera, Rohan},
title = {Abstract 17644: What Do AI-ECG Models See? Interpretable Representations and Morphologic Signatures Across Two Cardiac Diseases},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.17644}
}
EUVIMED