EUVIMEDEUVIMED entdecken
Crossref

Abstract 15818: Impact of Aortic Asymmetry on Measurement Discrepancies Between CTA, MRA, and TTE

Jonathan Dullea, Minel Soroa, Matthew Tomey, Tara Naib, Elbert Williams, Ismail El-Hamamsy, stamatios lerakis, Solomon Bienstock, Amy R Kontorovich

Circulation · 02.11.2026 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.15818 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Jonathan Dullea und 8 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Thoracic aorta dimension characterization in patients with aortic dilation is critical for disease surveillance. The 2022 ACC/AHA Aortic Disease Guidelines recommend interval imaging with transthoracic echocardiogram (TTE), computed tomography (CT), or magnetic resonance (MR) imaging without specification of a preferred modality, while the American Society of Echocardiography suggest TTE if previously shown to agree with CT/MR. TTE has previously been found to underestimate aortic diameters. The magnitude of discrepancy in relation to aortic geometry remains under characterized.

Methods

We retrospectively queried an IRB-approved institutional imaging database for patients imaged from 6/2013 to 6/2025. TTE measurements were also collected if within 6 months of CT or MRI. Patients with interval surgery or known progression were excluded. Measurements were re-performed if not reported. Agreement between modalities was assessed using Bland-Altman analysis. Linear regression was used to evaluate the relationship between measurement differences and aortic asymmetry (percent difference in max vs min diameter).

Results

66 patients (42% female, mean age 57.2) met inclusion criteria. CTA vs MRA showed no statistically significant bias at the sinus of Valsalva (SoV) (n = 59) or ascending aorta (AAo) (n = 62). At the aortic arch (AoArch), there was a small statistically significant bias (-0.09 cm, n = 42, p = 0.031). The limits of agreement were -0.32 to 0.37 cm at the SoV, -0.52 to 0.49 cm at the AAo, and -0.61 to 0.42 cm at the arch. No relationship was found between aortic asymmetry or scan interval and CTA/MRA disagreement. CTA measured the SoV on average 0.3 cm larger than TTE (n=33), demonstrating statistically significant bias by Bland-Altman. No significant bias was seen at the AAo (n=26) or arch (n=17). Limits of agreement were widest at the SoV (-0.64 to 1.24 cm), compared with the AAo (-0.78 to 0.53 cm) and arch (-1.11 to 0.84 cm). At the SoV, aortic asymmetry was associated with greater CTA-TTE measurement discrepancy: a 10% increase in asymmetry corresponded to a 0.21 cm increase in error (p=0.0011). No such relationship was observed at other segments.

Conclusion

CTA and MRA demonstrate superior agreement compared with CTA and TTE. The poorest agreement occurs at the SoV, where increasing asymmetry predicts greater CTA-TTE discrepancy. These findings suggest TTE may be less reliable for proximal aortic surveillance in patients with SoV asymmetry.

Zitieren

APA

Dullea, J., Soroa, M., Tomey, M., Naib, T., Williams, E., El-Hamamsy, I., lerakis, S., Bienstock, S., & Kontorovich, A. R. (2026). Abstract 15818: Impact of Aortic Asymmetry on Measurement Discrepancies Between CTA, MRA, and TTE. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.15818

Vancouver

Dullea J, Soroa M, Tomey M, Naib T, Williams E, El-Hamamsy I, et al. Abstract 15818: Impact of Aortic Asymmetry on Measurement Discrepancies Between CTA, MRA, and TTE. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.15818

BibTeX
@article{Dullea2026,
  author = {Dullea, Jonathan and Soroa, Minel and Tomey, Matthew and Naib, Tara and Williams, Elbert and El-Hamamsy, Ismail and lerakis, stamatios and Bienstock, Solomon and Kontorovich, Amy R},
  title = {Abstract 15818: Impact of Aortic Asymmetry on Measurement Discrepancies Between CTA, MRA, and TTE},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.15818}
}
Kostenlos starten →