Abstract 13620: Snare Assisted Deployment of Self Expanding Transcatheter Aortic Valve in a Failed Perceval Sutureless Bioprosthesis

Drashti Desai, Laith Derbas, Enrique Ramirez Merced, Gabriela Enid Arizmendi Velez, Hafiz Hussain

Circulation · 02.11.2026 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.13620 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Drashti Desai und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

TAVI/TAVR ; Valvuloplasty ; Structural heart disease intervention ; Valvular heart disease ; Aortic valve stenosis Introduction: Valve in valve Transcatheter Aortic Valve (ViV-TAVR) is established for failed surgical bioprostheses. The Perceval sutureless bioprosthesis has a tall self-expanding nitinol frame which poses unique challenges with difficult anatomy like horizontal aorta and severe aortic calcification further complicating valve delivery and alignment. We describe a snare assisted technique to achieve successful ViV-TAVR when standard methods failed. Patient Information (De-identified): An 81-year-old female with multiple comorbidities presented with NYHA Class III heart failure. Society of Thoracic Surgeons (STS) predicted mortality was 22.3%. She had prior surgical aortic valve replacement with a Perceval bioprosthesis, complicated by structural degeneration and severe prosthetic aortic stenosis. Clinical Findings and Timeline: TTE demonstrated mean gradient 47 mmHg and peak gradient 71 mmHg across the failed prosthesis. Left ventricular end-diastolic pressure (LVEDP) was 22 mmHg. Prohibitive surgical risk prompted referral for ViV-TAVR. Diagnostic Assessment and Reasoning: Perceval structural degeneration causing severe prosthetic aortic stenosis was confirmed. Anatomic risk factors like annular calcification, horizontal aortic root and unfavorable arch angulation predicted difficulty for coaxial transcatheter delivery. Therapeutic Intervention: Right femoral access was obtained via 18-French sheath. After retrograde crossing and wire positioning, balloon aortic valvuloplasty (BAV) was performed at 160 bpm. A 26 mm self-expanding transcatheter valve failed to achieve coaxial alignment through the Perceval frame despite sequential escalation with techniques like exchange to a stiffer wire (Lunderquist), rotational maneuvers, sheath upsizing to 20-French, and dual buddy wire support. A goose-neck snare then engaged the delivery system nose cone, mechanically redirecting its trajectory. Deployment was achieved at 120 bpm with excellent frame-in-frame alignment. Follow up, Outcomes and Adverse Events: Post procedural TTE confirmed no paravalvular leak, peak velocity 1.6 m/s, mean gradient 6.3 mmHg. The patient was discharged in stable condition. Discussion and Synthesis: The Perceval frame’s nitinol profile and tall self-anchoring architecture create a narrow corridor resisting standard delivery. Goose-neck snares are established for device retrieval; their use as a directional guide represents a bailout strategy. Other techniques such as transseptal antegrade access carry greater risk. Snare-assisted delivery is a safe, reproducible option for structural heart teams managing degenerated Perceval valves.

Zitieren

APA

Desai, D., Derbas, L., Merced, E. R., Velez, G. E. A., & Hussain, H. (2026). Abstract 13620: Snare Assisted Deployment of Self Expanding Transcatheter Aortic Valve in a Failed Perceval Sutureless Bioprosthesis. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.13620

Vancouver

Desai D, Derbas L, Merced ER, Velez GEA, Hussain H. Abstract 13620: Snare Assisted Deployment of Self Expanding Transcatheter Aortic Valve in a Failed Perceval Sutureless Bioprosthesis. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.13620

BibTeX
@article{Desai2026,
  author = {Desai, Drashti and Derbas, Laith and Merced, Enrique Ramirez and Velez, Gabriela Enid Arizmendi and Hussain, Hafiz},
  title = {Abstract 13620: Snare Assisted Deployment of Self Expanding Transcatheter Aortic Valve in a Failed Perceval Sutureless Bioprosthesis},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.13620}
}
Kostenlos starten →