Abstract (Originalsprache)
Background
Cryptogenic stroke (CS) accounts for approximately 20-30% of all ischemic strokes. Long-term rhythm monitoring following cryptogenic stroke is a class IIa recommendation in current guidelines. However, sex-based differences in implantable loop recorder (ILR) utilization and subsequent atrial fibrillation (AF)/Flutter detection remain incompletely characterized. Research Question: Are there sex-based differences in ILR utilization and subsequent AF/Flutter detection in patients with CS?
Methods
Using the TriNetX Research Network, we identified two cohorts of adults with CS and no prior AF/Flutter diagnosis: male patients (N = 576,013) and female patients (N = 603,975). We also identified two cohorts of adults with CS, no diagnosis of AF/Flutter prior to CS, and ILR implantation within one year after CS: male patients (N = 7,595) and female patients (N = 7,622). The primary outcome was ILR implantation following CS, while the secondary outcome was AF/Flutter detection following ILR implantation. Propensity score matching on demographics, comorbidities, thrombolytic administration, and mechanical thrombectomy yielded 442,891 matched patients for the determination of the primary outcome. The same parameters for propensity score matching yielded 4,835 matched patients for the determination of the secondary outcome.
Results
Female patients underwent ILR implantation significantly less frequently than males at 3 months (HR 0.91, 95% CI 0.86-0.96), 6 months (HR 0.92, 95% CI 0.88-0.97), and 12 months (HR 0.94, 95% CI 0.90-0.98) following cryptogenic stroke. Among ILR recipients, females demonstrated modestly lower AF/Flutter detection over 36 months (HR 0.89, 95% CI 0.83-0.95; log-rank p = 0.0007). Landmark analyses showed lower detection in females at 6 months (13.2% vs. 14.5%, p = 0.04) and 36 months (24.7% vs. 27.1%, p = 0.001), with similar rates at 3 months, 12 months, and 18 months.
Conclusions
Female patients underwent ILR implantation less frequently following cryptogenic stroke despite substantial rates of subsequent AF/Flutter detection. While females demonstrated modestly lower AF/Flutter detection over long-term follow-up, substantial occult AF/Flutter burden was identified in both sexes, with approximately one-quarter of ILR recipients diagnosed with AF/Flutter within 36 months. These findings support broader utilization of long-term rhythm monitoring following cryptogenic stroke regardless of sex.
Zitieren
APA
Kumar, D., Han, S., Heath, J., Miks, C., & Dominic, P. (2026). Abstract 13331: Sex Based Differences in Implantable Loop Recorder Utilization and Atrial Fibrillation/Flutter Detection Following Cryptogenic Stroke. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.13331
Vancouver
Kumar D, Han S, Heath J, Miks C, Dominic P. Abstract 13331: Sex Based Differences in Implantable Loop Recorder Utilization and Atrial Fibrillation/Flutter Detection Following Cryptogenic Stroke. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.13331
BibTeX
@article{Kumar2026,
author = {Kumar, Divyesh and Han, Sangwoo and Heath, Jacob and Miks, Charles and Dominic, Paari},
title = {Abstract 13331: Sex Based Differences in Implantable Loop Recorder Utilization and Atrial Fibrillation/Flutter Detection Following Cryptogenic Stroke},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.13331}
}
EUVIMED