Abstract (Originalsprache)

Background

The sinuses of Valsalva (SoV) constitute a vital anatomical component of the aortic root and are critical to the mechanical kinematics of the aortic valve. Research Questions: The hemodynamic importance of the native geometric properties of the SoV remains insufficiently investigated, and current commercial sinus-containing artificial vascular grafts are unable to mimic in vivo physiological hemodynamics.

Methods

Patient-specific three-dimensional aortic root models were reconstructed from aortic root CTA images of five healthy subjects. A dilation-erosion algorithm was applied to exclude the SoV geometry, generating two groups of models: one with intact SoV and one without. Computational fluid dynamics (CFD) simulations were performed under two flow regimes — pulsatile flow and steady flow (5 L/min) — with flow imposed in two directions: forward (systole) and reverse (diastole). In total, eight comparative flow scenarios were established. Key hemodynamic parameters analyzed included trans-sinus pressure gradient (PG), time-averaged wall pressure(TAWP) and time-averaged wall shear stress (TAWSS).

Results

For pulsatile flow, the model with sinuses yielded significantly higher PG for both forward flow ( p =0.013) and reverse flow ( p =0.024), relative to the non- sinus model. In contrast, under steady flow, the rises in forward-flow PG ( p =0.068) and reverse-flow PG ( p =0.420) in the sinus-containing model were statistically insignificant compared with the non-sinus counterpart (Figure 1). Compared with steady flow, pulsatile flow generated greater TAWP and TAWSS amplitudes and intensified spatial heterogeneity on the sinus wall, with substantially elevated TAWP and TAWSS detected on this wall during reverse flow. In all tested flow regimes, the non-sinus model displayed uniformly distributed TAWP and TAWSS.(Figure 2).

Conclusions

This study elucidates the complex influences of SoV geometry on energy loss and wall pressure and shear stress. The anatomical geometry of the SoV features inherent anteroposterior structural asymmetry, which carries important hemodynamic implications. During cardiac diastole, the sinus wall bears elevated stress, which may mitigate mechanical impact on the aortic valve. The findings of this study may provide design references for the development of novel sinus-containing vascular grafts with improved physiological fidelity.

Zitieren

APA

Fan, H., meng, J., Sun, Z., wei, R., jin, M., luo, B., qin, J., & zhang, Y. (2026). Abstract 11528: Computational Fluid Dynamics Evaluation of Hemodynamic Effects of Sinuses of Valsalva Under Different Flow Conditions. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.11528

Vancouver

Fan H, meng J, Sun Z, wei R, jin M, luo B, et al. Abstract 11528: Computational Fluid Dynamics Evaluation of Hemodynamic Effects of Sinuses of Valsalva Under Different Flow Conditions. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.11528

BibTeX
@article{Fan2026,
  author = {Fan, Hongguang and meng, jian and Sun, Zhengyang and wei, runjie and jin, mansu and luo, bin and qin, jinjin and zhang, yaxuan},
  title = {Abstract 11528: Computational Fluid Dynamics Evaluation of Hemodynamic Effects of Sinuses of Valsalva Under Different Flow Conditions},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.11528}
}
Kostenlos starten →