DOI: 10.11607/jomi.11298 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Oral & Maxillofacial Implants, 2025. Verfasst von Hossein Salehivaziri und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Mandible, Crowns, Dental Implants, Dental Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the distribution of stress in the bone around extra-short posterior mandibular implants to replace two molar teeth in six different treatment plans. MATERIALS AND METHODS: In this experimental study, preexisting CBCT data sets were imported into image-processing software (Mimics and 3-matic, Materialise) to create accurate 3D mandibular contours using finite element analysis (FEA). A total of 18 models for the reconstruction of the mandibular first and second molars were created based on the implant diameter, crown height, and splinted or nonsplinted form, with a 100-N load applied at a 30-degree angle. Two extra-short implants with a length of 4 mm and a diameter of 4.1 mm and/or 4.8 mm were used; the crown heights were 15 mm, 12.5 mm, and 10 mm, depending on the model. RESULTS: The study of stresses in cortical bone, trabecular bone, implants, and crowns revealed that the highest stress levels (ie, 118.27 MPa in cortical bone) were associated with the treatment plan involving two implants with a diameter of 4.1 mm without a splint and a crown height of 15 mm. Conversely, the lowest amount of stress (ie, 29.12 MPa in cortical bone) was observed in the treatment plan with two implants with a diameter of 4.8 mm without a splint and a crown height of 10 mm. Crown height influenced stress the most (≤ 237.6% increase), followed by diameter (≤ 63.7% reduction, weakened at higher crowns), while the type of splinting effects varied (ie, +122.7% crown stress increase in specific cases); cortical bone stayed below a 130 MPa safe zone, but trabecular bone often exceeded 10 MPa. CONCLUSIONS: Increasing the height of the crown in nonsplinted implants leads to an increase in stress distribution in all cases of the treatment plan outlined in this study, with statistical analysis suggesting trabecular bone risk and a need for fatigue studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MandibleCrownsDental ImplantsDental Prosthesis DesignDental Stress AnalysisFinite Element AnalysisHumansCone-Beam Computed TomographyMolarStress, MechanicalImaging, Three-Dimensional

Stichwörter der Autor:innen

biomechanicsdental crownsfinite element analysismandibular reconstructionshort implantsstress distribution

Substanzen

Dental Implants

Zitieren

APA

Salehivaziri, H., Yousefimanesh, H., Hagh, L. G., & Jahangirnezhad, M. (2025). Evaluation of the Effects of Diameter, Length, Splinted or Non- Splinted Forms, and Crown-to-Implant Ratio on the Stress Distribution around Extra-Short Implants in the Posterior Mandible: Finite Element Analysis. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11298

Vancouver

Salehivaziri H, Yousefimanesh H, Hagh LG, Jahangirnezhad M. Evaluation of the Effects of Diameter, Length, Splinted or Non- Splinted Forms, and Crown-to-Implant Ratio on the Stress Distribution around Extra-Short Implants in the Posterior Mandible: Finite Element Analysis. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11298

BibTeX
@article{Salehivaziri2025,
  author = {Salehivaziri, Hossein and Yousefimanesh, Hojatollah and Hagh, Leila Golpasand and Jahangirnezhad, Mahmoud},
  title = {Evaluation of the Effects of Diameter, Length, Splinted or Non- Splinted Forms, and Crown-to-Implant Ratio on the Stress Distribution around Extra-Short Implants in the Posterior Mandible: Finite Element Analysis},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2025},
  doi = {10.11607/jomi.11298}
}
Kostenlos starten →