Significance of Primary Stability in Non-Immediate Loaded Dental Implants: A Systematic Review & Meta-Analysis
The International Journal of Prosthodontics · 2025
DOI: 10.11607/ijp.9115 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift The International Journal of Prosthodontics, 2025. Verfasst von Nahal Razaghi und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Dental Implants, Osseointegration, Dental Implantation, Endosseous, Dental Prosthesis Retention. Die Arbeit wurde bisher 3-mal zitiert (Crossref).
Abstract (Originalsprache)
PURPOSE: To determine the significance of primary stability, as measured by insertion torque (IT) and/or implant stability quotient (ISQ), in achieving osseointegration of nonimmediately loaded implants. MATERIALS AND METHODS: Three electronic databases were searched. Studies were included if they measured IT and/ or ISQ at time of placement and reported survival for up to 1 year. For studies where at least one implant failed, a random effects meta-analysis was carried out for the odds of survival. RESULTS: In total, 3,431 publications were screened, and 79 were accepted for analysis. These included 28 RCTs, 12 CCTs, 10 cohort studies, and 29 case series. Overall, 21 studies provided individual implant data for a total of 1,413 implants, and 7 studies were included for meta-analysis. A total of 264 implants were placed with ISQ < 60 and 249 with IT < 35. Survival of implants placed with ISQ < 60 and IT < 35 were 97.7% and 95.2%, respectively. Meta-analysis found no evidence that an ISQ ≥ 60 was less likely to fail compared to ISQ < 60 (OR 0.54, 95% CI 0.17 to 1.75, P = .31), or that an IT ≥ 35 resulted in higher odds of failure compared to IT < 35 (OR 0.82, 95% CI 0.13 to 5.40, P = .84). CONCLUSIONS: This study found no evidence to support that an IT ≥ 35 or ISQ ≥ 60 for nonimmediately loaded implants results in higher survival than those below these values.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Zitieren
APA
Razaghi, N., Gill, T., Patankar, A., Petrie, A., & Shahdad, S. (2025). Significance of Primary Stability in Non-Immediate Loaded Dental Implants: A Systematic Review & Meta-Analysis. The International Journal of Prosthodontics. https://doi.org/10.11607/ijp.9115
Vancouver
Razaghi N, Gill T, Patankar A, Petrie A, Shahdad S. Significance of Primary Stability in Non-Immediate Loaded Dental Implants: A Systematic Review & Meta-Analysis. The International Journal of Prosthodontics. 2025. doi:10.11607/ijp.9115
BibTeX
@article{Razaghi2025,
author = {Razaghi, Nahal and Gill, Thomas and Patankar, Anuya and Petrie, Aviva and Shahdad, Shakeel},
title = {Significance of Primary Stability in Non-Immediate Loaded Dental Implants: A Systematic Review & Meta-Analysis},
journal = {The International Journal of Prosthodontics},
year = {2025},
doi = {10.11607/ijp.9115}
}