EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY-SA 4.0

Impact of Ultrasound Cycloplasty on Intraocular Pressure and Clinical Outcomes in Angle-Closure Glaucoma: A Systematic Review and Meta Analysis

Hisyam Hartaman Putra, Rahmadina Djumain, Dafi Irsan Satria, Aan Tri Lutfi Muhammad, Brian Arditya Mahendra

Oftalmologi Jurnal Kesehatan Mata Indonesia · 31.12.2025 · 7 (3) · 119

DOI: 10.11594/ojkmi.v7i3.95 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Oftalmologi Jurnal Kesehatan Mata Indonesia, online erschienen am 31.12.2025. Verfasst von Hisyam Hartaman Putra und 4 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Angle-closure glaucoma (ACG) is a leading cause of permanent blindness, especially in Asia. Conventional therapies often fail to provide long-term intraocular pressure (IOP) control. Ultrasound Cycloplasty (UCP), a high-intensity focused ultrasound (HIFU) technology, lowers IOP through selective coagulation of the ciliary processes. This review aimed to evaluate the effectiveness and safety of UCP in patients with ACG.

Methods

A literature search was conducted in PubMed, Scopus, and Wiley until October 2025. Inclusion studies included ACG patients undergoing UCP with reported IOP outcomes, antiglaucoma medication use, and complications. Meta-analysis used a random-effects model and sensitivity analysis with a fixed-effects model.

Results

Four studies involving 142 eyes were analyzed. UCP reduced IOP by 18.12 mmHg, though not statistically significant (95% CI –1.27 to 37.51) with very high heterogeneity (I² = 99%). Antiglaucoma medication use decreased significantly (MD 1.79; p = 0.02). Early/mild complications were more common than late/severe complications. Sensitivity analysis showed stable results with reduced heterogeneity.

Conclusion

UCP is potentially effective in reducing IOP and antiglaucoma medication use in ACG patients, with an acceptable safety profile. However, considerable inter-study variability suggests that prospective studies are needed.

Zitieren

APA

Putra, H. H., Djumain, R., Satria, D. I., Muhammad, A. T. L., & Mahendra, B. A. (2025). Impact of Ultrasound Cycloplasty on Intraocular Pressure and Clinical Outcomes in Angle-Closure Glaucoma: A Systematic Review and Meta Analysis. Oftalmologi Jurnal Kesehatan Mata Indonesia, 7(3), 119. https://doi.org/10.11594/ojkmi.v7i3.95

Vancouver

Putra HH, Djumain R, Satria DI, Muhammad ATL, Mahendra BA. Impact of Ultrasound Cycloplasty on Intraocular Pressure and Clinical Outcomes in Angle-Closure Glaucoma: A Systematic Review and Meta Analysis. Oftalmologi Jurnal Kesehatan Mata Indonesia. 2025;7(3):119. doi:10.11594/ojkmi.v7i3.95

BibTeX
@article{Putra2025,
  author = {Putra, Hisyam Hartaman and Djumain, Rahmadina and Satria, Dafi Irsan and Muhammad, Aan Tri Lutfi and Mahendra, Brian Arditya},
  title = {Impact of Ultrasound Cycloplasty on Intraocular Pressure and Clinical Outcomes in Angle-Closure Glaucoma: A Systematic Review and Meta Analysis},
  journal = {Oftalmologi Jurnal Kesehatan Mata Indonesia},
  year = {2025},
  volume = {7},
  number = {3},
  pages = {119},
  doi = {10.11594/ojkmi.v7i3.95}
}
Kostenlos starten →