EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Uncertainty-aware circular residual U-Net for electrocardiogram denoising under realistic nonstationary noise

Ahmad Rifai, Siti Nurmaini, Bhakti Yudho Suprapto, Radiyati Umi Partan, Firdaus Firdaus

Bulletin of Electrical Engineering and Informatics · 01.12.2026 · 15 (6) · 4989-5002

DOI: 10.11591/eei.v15i6.13968 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of Electrical Engineering and Informatics, online erschienen am 01.12.2026. Verfasst von Ahmad Rifai und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrocardiogram (ECG) signals in ambulatory monitoring are frequently degraded by nonstationary baseline wander (BW), muscle artifact (MA), and electrode-motion (EM) artifact. This study proposed an uncertainty-aware circular residual U-Net integrating circular convolution, residual-noise prediction, a morphology-aware boundary loss, and Monte Carlo (MC) dropout. Clean QT database segments were contaminated with Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) noise stress test database noise at input signal-to-noise ratios (SNR) from -6 to 24 dB. Evaluation on 2,560 test segments compared the proposed model with db4 wavelet denoising, convolutional neural network-denoising autoencoder (CNN-DAE), a zero-padded U-Net, and a circular U-Net. The proposed model achieved an output SNR of 11.6789 dB and waveform correlation of 0.9309, with the lowest root mean square error (RMSE), mean absolute error (MAE), percentage root-mean-square difference (PRD), derivative MAE, and boundary MAE of 0.1820, 0.1382, 32.5572, 0.0236, and 0.1678, respectively. Its peak-amplitude error of 0.1998 was comparable to the circular U-Net. Output SNR exceeded CNN-DAE and wavelet denoising by 3.1449 and 2.8925 dB. Predictive uncertainty strongly correlated with reconstruction error (r=0.8239, p

Zitieren

APA

Rifai, A., Nurmaini, S., Suprapto, B. Y., Partan, R. U., & Firdaus, F. (2026). Uncertainty-aware circular residual U-Net for electrocardiogram denoising under realistic nonstationary noise. Bulletin of Electrical Engineering and Informatics, 15(6), 4989-5002. https://doi.org/10.11591/eei.v15i6.13968

Vancouver

Rifai A, Nurmaini S, Suprapto BY, Partan RU, Firdaus F. Uncertainty-aware circular residual U-Net for electrocardiogram denoising under realistic nonstationary noise. Bulletin of Electrical Engineering and Informatics. 2026;15(6):4989-5002. doi:10.11591/eei.v15i6.13968

BibTeX
@article{Rifai2026,
  author = {Rifai, Ahmad and Nurmaini, Siti and Suprapto, Bhakti Yudho and Partan, Radiyati Umi and Firdaus, Firdaus},
  title = {Uncertainty-aware circular residual U-Net for electrocardiogram denoising under realistic nonstationary noise},
  journal = {Bulletin of Electrical Engineering and Informatics},
  year = {2026},
  volume = {15},
  number = {6},
  pages = {4989--5002},
  doi = {10.11591/eei.v15i6.13968}
}
Kostenlos starten →