Comparative study of CNN and fused 2D CNN-LSTM with CWT and STFT for power quality disturbance classification

Bouchra Feriel Khaldi, Fatma Zohra Dekhandji, Abdelmadjid Recioui

Bulletin of Electrical Engineering and Informatics · 01.06.2026 · 15 (3) · 1984-2002

DOI: 10.11591/eei.v15i3.10719 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of Electrical Engineering and Informatics, online erschienen am 01.06.2026. Verfasst von Bouchra Feriel Khaldi und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The integration of solar and wind energy has increased electricity generation but also introduced power quality disturbances (PQDs) that threaten grid stability. This study examines the detection and classification of five PQD types—voltage sag, swell, interruption, harmonics, and normal conditions—across noisy environments (0, 10, 20, and 30 dB) signal-to-noise ratio (SNR). Traditional methods— support vector machine (SVM), random forest (RF), artificial neural networks (ANN), and 1D convolutional neural networks (1D CNN)—are evaluated on raw signal data, while advanced models—2D CNN and fused 2D CNN-LSTM—utilize time-frequency representations (continuous wavelet transform (CWT) and short-time Fourier transform (STFT)). Results show that deep learning (DL) models achieve high accuracy even in noisy environments, with the fused 2D CNNLSTM using CWT outperforming all other methods. Noise adversely affects feature extraction, with CWT consistently outperforming STFT under low SNR conditions. These findings demonstrate that combining DL models with robust time-frequency analysis and temporal modeling enhances PQD classification and supports dependable monitoring in smart grid environments.

Zitieren

APA

Khaldi, B. F., Dekhandji, F. Z., & Recioui, A. (2026). Comparative study of CNN and fused 2D CNN-LSTM with CWT and STFT for power quality disturbance classification. Bulletin of Electrical Engineering and Informatics, 15(3), 1984-2002. https://doi.org/10.11591/eei.v15i3.10719

Vancouver

Khaldi BF, Dekhandji FZ, Recioui A. Comparative study of CNN and fused 2D CNN-LSTM with CWT and STFT for power quality disturbance classification. Bulletin of Electrical Engineering and Informatics. 2026;15(3):1984-2002. doi:10.11591/eei.v15i3.10719

BibTeX
@article{Khaldi2026,
  author = {Khaldi, Bouchra Feriel and Dekhandji, Fatma Zohra and Recioui, Abdelmadjid},
  title = {Comparative study of CNN and fused 2D CNN-LSTM with CWT and STFT for power quality disturbance classification},
  journal = {Bulletin of Electrical Engineering and Informatics},