EUVIMEDEUVIMED entdecken
Crossref

P-338: HbA1c overestimates glycemic burden compared to glucose management indicator in type 1 diabetes

P-338: HbA1c überschätzt die glykämische Belastung im Vergleich zum Glucose Management Indicator bei Typ-1-Diabetes

S d S F Lemos, G L Torres, L P S Lima, J P A Freitas, N C Monteiro, M d L P Machado, L M Martins, B F d O Santos, T Trevisan, N O d Santana

Hormone Research in Paediatrics · 04.11.2026 · 99 (Supplement_4)

DOI: 10.1159/hrp/adaag020.396 ↗

Auf einen Blick

In einer 6-monatigen Studie bei 53 Personen mit Typ-1-Diabetes stimmten HbA1c und GMI nur schlecht überein. HbA1c lag meist über dem GMI.

Fragestellung

Wie gut stimmen laborbestimmtes HbA1c und aus CGM abgeleiteter GMI nach 6 Monaten überein, und wie hängt TIR mit HbA1c zusammen?

Methode

6-monatige Längsschnittstudie bei 53 Personen mit Typ-1-Diabetes in einer endokrinologischen Ambulanz in Nordost-Brasilien; intermittierend gescanntes CGM; Vergleich von HbA1c und GMI mit Bland-Altman, ICC und Pearson-Korrelation; lineare Regression für TIR und HbA1c.

Ergebnisse

Mittlere Abweichung +0,80 % zugunsten von HbA1c; 27 % lagen innerhalb von 0,5 %, 32 % wichen um mehr als 1 % ab. ICC 0,616, Pearson r=0,838. TIR und HbA1c: r=-0,789; R2=0,62.

Schlussfolgerung der Autor:innen

HbA1c und GMI sind in dieser Population nicht austauschbar. Bei den meisten Teilnehmenden lag HbA1c über dem GMI.

Kernaussagen

  • HbA1c lag im Mittel 0,80 % über dem GMI
  • Nur 27 % lagen innerhalb von 0,5 % Abweichung
  • TIR und HbA1c waren stark negativ korreliert

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Hormone Research in Paediatrics, online erschienen am 04.11.2026. Verfasst von S d S F Lemos und 9 weiteren Autor:innen.

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Glycated hemoglobin (HbA1c) and glucose management indicator (GMI) derived from continuous glucose monitoring (CGM) estimate glycemic control through distinct mechanisms. Whether GMI can reliably substitute HbA1c in clinical decision-making for type 1 diabetes (T1D) remains uncertain.

Objectives

To evaluate the agreement between laboratory HbA1c and CGM-derived GMI at six months, and to explore the association between time in range (TIR) and HbA1c in individuals with T1D.

Methods

A 6-month longitudinal study enrolled 53 individuals with T1D from a public endocrinology clinic in Northeastern Brazil. All participants used an intermittently scanned CGM. HbA1c was measured at baseline and at six months. Agreement between HbA1c and GMI at six months was assessed using the Bland-Altman method, intraclass correlation coefficient (ICC), and Pearson correlation. The association between TIR and HbA1c was assessed by linear regression.

Results

A total of 32(60.4%) of participants were under 25 years of age. Baseline HbA1c was 9.06±1.86%, diabetes duration was 11±8.72 years, and GMI at six months was 7.64±1.04%. Agreement between HbA1c and GMI was poor: mean bias was +0.80% (HbA1c systematically higher than GMI), with proportional bias indicating greater discrepancy in participants with worse glycemic control. Only 27% showed agreement within 0.5%, while 32% had discrepancies above 1%. ICC was moderate (0.616), despite strong Pearson correlation (r=0.838). TIR and HbA1c showed strong negative correlation (r=-0.789; R2=0.62), with each 10% increase in TIR corresponding to a 0.8% reduction in HbA1c.

Conclusions

HbA1c and GMI are not interchangeable in this population. In most participants, HbA1c exceeded GMI, revealing a predominantly unidirectional discrepancy whose magnitude surpassed previously reported rates, consistent with the proportional bias observed and the high baseline glycemic burden of this cohort, with direct implications for therapeutic decision-making.

Zitieren

APA

Lemos, S. D. S. F., Torres, G. L., Lima, L. P. S., Freitas, J. P. A., Monteiro, N. C., Machado, M. D. L. P., Martins, L. M., Santos, B. F. D. O., Trevisan, T., & Santana, N. O. D. (2026). P-338: HbA1c overestimates glycemic burden compared to glucose management indicator in type 1 diabetes. Hormone Research in Paediatrics, 99(Supplement_4). https://doi.org/10.1159/hrp/adaag020.396

Vancouver

Lemos SDSF, Torres GL, Lima LPS, Freitas JPA, Monteiro NC, Machado MDLP, et al. P-338: HbA1c overestimates glycemic burden compared to glucose management indicator in type 1 diabetes. Hormone Research in Paediatrics. 2026;99(Supplement_4). doi:10.1159/hrp/adaag020.396

BibTeX
@article{Lemos2026,
  author = {Lemos, S d S F and Torres, G L and Lima, L P S and Freitas, J P A and Monteiro, N C and Machado, M d L P and Martins, L M and Santos, B F d O and Trevisan, T and Santana, N O d},
  title = {P-338: HbA1c overestimates glycemic burden compared to glucose management indicator in type 1 diabetes},
  journal = {Hormone Research in Paediatrics},
  year = {2026},
  volume = {99},
  number = {Supplement_4},
  doi = {10.1159/hrp/adaag020.396}
}
Kostenlos starten →