P-265: Clinical impact of continuous glucose monitoring use in patients followed at a specialized outpatient clinic in the Brazilian public health system

F Vieira de Souza Canuto, E Lopes Vieira Marques, C Sousa Costa Pessoa, N Melo de Almeida, R Carolina Guerra do Prado, R de Moraes Oliveira Avendano, S Cristine Rodrigues de Souza

Hormone Research in Paediatrics · 04.11.2026 · 99 (Supplement_4)

DOI: 10.1159/hrp/adaag020.323 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hormone Research in Paediatrics, online erschienen am 04.11.2026. Verfasst von F Vieira de Souza Canuto und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Childhood and adolescence correspond to critical phases of physical growth, brain maturation, and emotional development; therefore, glycemic fluctuations impact proper development. The use of Continuous Glucose Monitoring (CGM) in patients in this age group with Type 1 Diabetes Mellitus (DM1) represents an advancement in clinical care and quality of life. Providing access to this technology in the public health system may promote equity and improve metabolic control.

Objectives

To evaluate the clinical effectiveness of CGM use in children and adolescents with DM1 followed in a specialized outpatient clinic.

Methods

An observational, quantitative, cross-sectional study, based on medical records of 189 patients, of whom 29 were excluded due to missing HbA1c data, 106 using self-monitoring of blood glucose (SMBG) and 54 using CGM, aged 2 to 18 years, followed accompanied by a multidisciplinary care at the Specialized Center for Diabetes, Obesity, and Hypertension of the Federal District, Brazil. Statistical analysis was performed using Student’s t-test. Approved by the Ethics Committee (No. 95934426.2.0000.5553).

Results

The mean age of the participants was 11.8 years, with mean duration of diabetes of 4.7 years. The CGM group had an average HbA1c of 7.4%, while the group that used a glucometer had an average of 9.2%, with a statistically significant difference between the groups (p < 0.001).

Conclusions

Despite the socioeconomic limitations faced by patients in the public health service that hinder the adequate management of type 1 diabetes (T1D), the use of CGM was associated with better glycemic control compared to the use of a conventional glucometer. These findings suggest that expanding access to CGM may significantly improve care and reducing the risk of long-term complications in this population, particularly when combined with multidisciplinary care.

Zitieren

APA

Canuto, F. V. D. S., Marques, E. L. V., Pessoa, C. S. C., Almeida, N. M. D., Prado, R. C. G. D., Avendano, R. D. M. O., & Souza, S. C. R. D. (2026). P-265: Clinical impact of continuous glucose monitoring use in patients followed at a specialized outpatient clinic in the Brazilian public health system. Hormone Research in Paediatrics, 99(Supplement_4). https://doi.org/10.1159/hrp/adaag020.323

Vancouver

Canuto FVDS, Marques ELV, Pessoa CSC, Almeida NMD, Prado RCGD, Avendano RDMO, et al. P-265: Clinical impact of continuous glucose monitoring use in patients followed at a specialized outpatient clinic in the Brazilian public health system. Hormone Research in Paediatrics. 2026;99(Supplement_4). doi:10.1159/hrp/adaag020.323

BibTeX
@article{Canuto2026,
  author = {Canuto, F Vieira de Souza and Marques, E Lopes Vieira and Pessoa, C Sousa Costa and Almeida, N Melo de and Prado, R Carolina Guerra do and Avendano, R de Moraes Oliveira and Souza, S Cristine Rodrigues de},
  title = {P-265: Clinical impact of continuous glucose monitoring use in patients followed at a specialized outpatient clinic in the Brazilian public health system},
  journal = {Hormone Research in Paediatrics},
  year = {2026},
  volume = {99},
  number = {Supplement_4},
  doi = {10.1159/hrp/adaag020.323}
}