EUVIMEDEUVIMED entdecken
Multizentrische StudieStudienprotokollOpen Access · CC BY-NC 4.0

Target Weight Optimization based on a Modified VExUS Protocol in Hemodialysis: The VexHD Prospective Multi-Center Study

Patricia Muñoz Ramos, Alberto Ortiz, Ana B Sanz, Martín Giorgi, Paloma Ruiz López-Alvarado, Irene Oñate, Verónica Ruth Mercado, José Carlos de La Flor Merino, Marco Vaca Gallardo, María Lina León-Machado, Virginia López de la Manzanara, Mohammad Manouchehri und 5 weitere

Cardiorenal Medicine · 15.10.2026 · 16 (1) · 541-554

DOI: 10.1159/crm/abtag011 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Cardiorenal Medicine, online erschienen am 15.10.2026. Verfasst von Patricia Muñoz Ramos und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology, Hospital Universitario Infanta Leonor, Madrid, Spain. Hauptthemen laut MEDLINE: Renal Dialysis, Blood Pressure, Kidney Failure, Chronic, Body Weight. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Clinical examination has limitations in estimating fluid overload in hemodialysis patients. The aim of the present study was to evaluate the impact of target weight optimization using a modified Venous Excess Ultrasonography Score (VExUS) protocol on blood pressure control in euvolemic hemodialysis patients.

Methods

We enrolled clinically euvolemic patients in hemodialysis from ten Spanish centers. Baseline clinical data, bioimpedance, and an extensive panel of cardiac, congestion, and inflammatory biomarkers were collected. Patients with congestion on modified VExUS protocol (excluding intrarenal vessels) underwent protocol-driven ultrafiltration adjustments. Blood pressure, bioimpedance, and biomarkers were reassessed at study completion, and paired statistical analyses were performed.

Results

Among the 72 clinically euvolemic patients included (60% male, mean age 69 ± 18 years), 23 (32%) showed venous congestion on modified VExUS protocol and entered the intervention group and 49 were followed under routine care conditions (reference). Volume values obtained by bioimpedance spectroscopy were similar in the congestion intervention and non-congestion reference groups. After 4 weeks, the intervention group experienced a significant improvement in modified VExUS protocol parameters compared to baseline (2.1 ± 0.5 vs. 1.3 ± 0.5; p < 0.001) and a systolic blood pressure reduction compared with reference group participants (−14 [−37; 4] vs. 4 [−9; 14] mm Hg) (p = 0.025). The reduction in systolic blood pressure was more notable in patients with higher baseline values. There were no differences in hemodialysis tolerance or biomarker changes between intervention and reference group participants.

Conclusion

Modified VExUS protocol is a promising tool for evaluating volume overload and optimizing target weight. Its incorporation in the multiparametric assessment of target weight is associated with better blood pressure control.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisBlood PressureKidney Failure, ChronicBody WeightWater-Electrolyte ImbalanceHumansProspective StudiesMaleFemaleAgedUltrasonographyMiddle AgedElectric ImpedanceBiomarkersSpain

Stichwörter der Autor:innen

Blood pressureCongestionHemodialysisTarget weightVExUSVolume overload

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Department of Nephrology, Hospital Universitario Infanta Leonor, Madrid, Spain.
  • IIS-Fundación Jiménez Díaz UAM, Madrid, Spain.
  • RICORS 2040, Barcelona, Spain.
  • Department of Nephrology, Hospital Universitario de La Princesa, Madrid, Spain.
  • Department of Nephrology, Hospital Universitario de Burgos, Burgos, Spain.
  • Department of Nephrology, Hospital Universitario Infanta Sofía, Madrid, Spain.

Zitieren

APA

Muñoz Ramos, P., Ortiz, A., Sanz, A. B., Giorgi, M., Ruiz López-Alvarado, P., Oñate, I., Mercado, V. R., de La Flor Merino, J. C., Vaca Gallardo, M., León-Machado, M. L., López de la Manzanara, V., Manouchehri, M., Santos Alonso, C., Carrasco, S., Navas Jiménez, M. Á., de Sequera, P., & Quiroga, B. (2026). Target Weight Optimization based on a Modified VExUS Protocol in Hemodialysis: The VexHD Prospective Multi-Center Study. Cardiorenal Medicine, 16(1), 541-554. https://doi.org/10.1159/crm/abtag011

Vancouver

Muñoz Ramos P, Ortiz A, Sanz AB, Giorgi M, Ruiz López-Alvarado P, Oñate I, et al. Target Weight Optimization based on a Modified VExUS Protocol in Hemodialysis: The VexHD Prospective Multi-Center Study. Cardiorenal Medicine. 2026;16(1):541-554. doi:10.1159/crm/abtag011

BibTeX
@article{MuozRamos2026,
  author = {Muñoz Ramos, Patricia and Ortiz, Alberto and Sanz, Ana B and Giorgi, Martín and Ruiz López-Alvarado, Paloma and Oñate, Irene and Mercado, Verónica Ruth and de La Flor Merino, José Carlos and Vaca Gallardo, Marco and León-Machado, María Lina and López de la Manzanara, Virginia and Manouchehri, Mohammad and Santos Alonso, Carlos and Carrasco, Susana and Navas Jiménez, Miguel Ángel and de Sequera, Patricia and Quiroga, Borja},
  title = {Target Weight Optimization based on a Modified VExUS Protocol in Hemodialysis: The VexHD Prospective Multi-Center Study},
  journal = {Cardiorenal Medicine},
  year = {2026},
  volume = {16},
  number = {1},
  pages = {541--554},
  doi = {10.1159/crm/abtag011}
}