EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Artificial Intelligence-Based CTA Software for Real-World Detection of Large-Vessel Occlusion in Acute Ischemic Stroke

Nicola Morelli, Eugenia Rota, Marco Spallazzi, Marina Biondi, Paolo Immovilli

European Neurology · 10.07.2026 · 1-9

DOI: 10.1159/000553264 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift European Neurology, online erschienen am 10.07.2026. Verfasst von Nicola Morelli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Neuroradiology Unit, Guglielmo da Saliceto Hospital, Piacenza, Italy, nicola.morelli.md@gmail.com. Hauptthemen laut MEDLINE: Ischemic Stroke, Artificial Intelligence, Computed Tomography Angiography, Software. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Artificial intelligence (AI)-based tools for CT angiography (CTA) have been introduced to support rapid detection of large vessel occlusion (LVO) in acute ischemic stroke. Although regulatory approval has relied mainly on controlled clinical studies, evidence from routine clinical practice remains limited. This study aimed to assess the real-world diagnostic performance and workflow impact of the Brainomix e-CTA software.

Methods

We conducted a retrospective, single-center observational study including consecutive patients with suspected acute ischemic stroke who underwent multiphase CTA between May 2023 and May 2025. Automated LVO detection using e-CTA was compared with expert neuroradiologist interpretation as a pragmatic clinical reference standard. Diagnostic performance was evaluated using sensitivity, specificity, and accuracy. Sensitivity was additionally analyzed according to occlusion location. Inter-reader agreement was assessed using Cohen’s κ, and time to diagnostic conclusion with and without AI assistance was compared across readers with different experience levels.

Results

Among 531 CTA examinations, LVO was identified in 19% of cases. Overall LVO detection showed a sensitivity of 84%, specificity of 95%, and accuracy of 93%. Sensitivity was highest for ICA/proximal M1 occlusions (94%) and progressively decreased for intermediate (87%) and distal M1 occlusions (73%). Agreement between AI output and expert interpretation was excellent for ICA/proximal M1 occlusions (κ = 0.91) and moderate for distal M1 occlusions (κ = 0.48). AI assistance significantly reduced time to diagnostic conclusion across all reader profiles.

Conclusion

In routine clinical practice, Brainomix e-CTA showed highest diagnostic performance for ICA/proximal M1 occlusions and reduced time to diagnostic conclusion. However, lower sensitivity for intermediate and distal M1 occlusions and the exclusion of nontarget occlusions from the primary endpoint indicate that e-CTA should be used as an adjunctive workflow tool rather than as a standalone method for treatment decision-making.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ischemic StrokeArtificial IntelligenceComputed Tomography AngiographySoftwareCerebral AngiographyBrain IschemiaHumansRetrospective StudiesFemaleMaleAgedMiddle AgedSensitivity and SpecificityAged, 80 and over

Stichwörter der Autor:innen

Acute ischemic strokeArtificial intelligenceComputed tomography angiographyDiagnostic accuracyLarge vessel occlusion

Autor:innen und Institutionen

  • Neuroradiology Unit, Guglielmo da Saliceto Hospital, Piacenza, Italy, nicola.morelli.md@gmail.com.
  • Neurology Unit, San Giacomo Hospital, Novi Ligure, Italy.
  • Neurology Unit, University of Parma, Parma, Italy.
  • Neuroradiology Unit, Guglielmo da Saliceto Hospital, Piacenza, Italy.
  • Neurology Unit, Guglielmo da Saliceto Hospital, Piacenza, Italy.

Zitieren

APA

Morelli, N., Rota, E., Spallazzi, M., Biondi, M., & Immovilli, P. (2026). Artificial Intelligence-Based CTA Software for Real-World Detection of Large-Vessel Occlusion in Acute Ischemic Stroke. European Neurology, 1-9. https://doi.org/10.1159/000553264

Vancouver

Morelli N, Rota E, Spallazzi M, Biondi M, Immovilli P. Artificial Intelligence-Based CTA Software for Real-World Detection of Large-Vessel Occlusion in Acute Ischemic Stroke. European Neurology. 2026:1-9. doi:10.1159/000553264

BibTeX
@article{Morelli2026,
  author = {Morelli, Nicola and Rota, Eugenia and Spallazzi, Marco and Biondi, Marina and Immovilli, Paolo},
  title = {Artificial Intelligence-Based CTA Software for Real-World Detection of Large-Vessel Occlusion in Acute Ischemic Stroke},
  journal = {European Neurology},
  year = {2026},
  pages = {1--9},
  doi = {10.1159/000553264}
}
Kostenlos starten →