Reproducibility of Perfusion-Weighted and Diffusion-Weighted Magnetic Resonance Imaging in Patients with Ocular Tumours
Ocular Oncology and Pathology · 05.06.2026 · 1-9
DOI: 10.1159/000552801 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ocular Oncology and Pathology, online erschienen am 05.06.2026. Verfasst von Pieter A M Janssen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) can assess biological tumour characteristics of uveal melanoma (UM), the most common primary intraocular malignant tumour in adults. Recent studies propose that these techniques can aid in the differential diagnosis, provide prognostic information, and enable early assessment of treatment response following radiation therapy. However, it is important to determine the extent to which any observed differences can be attributable to true biological changes in the tumour rather than day-to-day physiological or measurement variations. Therefore, this study aimed to assess the reproducibility of ocular DWI and PWI measurements between two centres.
Method
In this prospective study, 15 patients with UM were included. Each patient underwent two MRIs at two different centres with a mean interval of 28 days (range: 12–43 days). Apparent diffusion coefficient (ADC), relative peak intensity, and outflow percentage of the tumour were compared between the two timepoints. Mean absolute differences between the two timepoints were calculated.
Results
Mean absolute differences between the two timepoints were 0.07 × 10−3 mm2/s (95% CI, 0.04–0.11) for ADC, 0.11 (95% CI, 0.04–0.18) for relative peak intensity, and 6 (95% CI, 3–10) percentage points for outflow percentage.
Conclusion
This study shows that DWI and PWI parameters demonstrate reproducibility in UM patients between two different centres, with variabilities smaller than differences typically observed in differential diagnosis or treatment response assessments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
- Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands.
- HollandPTC, Delft, The Netherlands.
Zitieren
APA
Janssen, P. A. M., Ferreira, T. A., Vu, T. H. K., Beenakker, J. W. M., & Klaassen, L. (2026). Reproducibility of Perfusion-Weighted and Diffusion-Weighted Magnetic Resonance Imaging in Patients with Ocular Tumours. Ocular Oncology and Pathology, 1-9. https://doi.org/10.1159/000552801
Vancouver
Janssen PAM, Ferreira TA, Vu THK, Beenakker JWM, Klaassen L. Reproducibility of Perfusion-Weighted and Diffusion-Weighted Magnetic Resonance Imaging in Patients with Ocular Tumours. Ocular Oncology and Pathology. 2026:1-9. doi:10.1159/000552801
BibTeX
@article{Janssen2026,
author = {Janssen, Pieter A M and Ferreira, Teresa A and Vu, T H Khanh and Beenakker, Jan-Willem M and Klaassen, Lisa},
title = {Reproducibility of Perfusion-Weighted and Diffusion-Weighted Magnetic Resonance Imaging in Patients with Ocular Tumours},
journal = {Ocular Oncology and Pathology},
year = {2026},
pages = {1--9},
doi = {10.1159/000552801}
}
EUVIMED