Effects of Pre-Dialysis Fluid Overload, Intradialytic Relative Blood Volume Levels, and Cumulative Ultrafiltration Volume on Pulse Wave-Derived Features during Hemodialysis: Results from a Longitudinal Cohort Study
Kidney and Blood Pressure Research · 12.05.2026 · 51 (1) · 378-393
DOI: 10.1159/000552495 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Kidney and Blood Pressure Research, online erschienen am 12.05.2026. Verfasst von Simon Krenn und 6 weiteren Autor:innen. Beteiligte Einrichtung: AIT Austrian Institute of Technology, Center for Health and Bioresources, Medical Signal Analysis, Vienna, Austria. Hauptthemen laut MEDLINE: Pulse Wave Analysis, Renal Dialysis, Blood Volume. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Arterial pulse wave-derived features (PWFs) reflect hemodynamic changes during hemodialysis, and while their use is not currently recommended by clinical practice guidelines, many PWFs are associated with patient outcomes beyond classical blood pressure measurements. Pre-dialysis fluid overload (FO), intradialytic relative blood volume (RBV), and cumulative ultrafiltration volume (cUFV) may influence PWFs, but these relationships remain incompletely characterized. We aimed to explore associations between FO, RBV, cUFV, and PWFs during hemodialysis.
Methods
We analyzed 79 hemodialysis sessions in 24 patients over 5 weeks. Each session included pre-dialysis bioimpedance spectroscopy, cuff-based pulse wave measurements every 15 min, and continuous RBV/cUFV monitoring. Associations between RBV or cUFV and 28 PWFs (including blood pressure measures, parameters of cardiac function, and various arterial wave features derived from pulse wave analysis) were assessed using confounder-adjusted generalized estimating equations. Repeated-measures correlation analysis evaluated within-patient associations between pre-dialysis FO and both initial PWF levels (median from the first 45 min) and their intradialytic changes (late minus early 45-min median).
Results
We analyzed 817 pulse wave measurements from 24 patients (21 men; median age 66 years). Overall, RBV was associated with 18/28 PWFs (64%) and cUFV with 10/28 (36%), with distinct patterns: independently of each other, RBV was associated mainly with stroke volume, cardiac output, heart rate, systolic and reflected intensity peaks, and excess pressure; cUFV mainly with diastolic blood pressure, peripheral resistance, reservoir pressure, and the ratio of forward intensity peaks. Significant early-to-late intradialytic changes in PWFs included a decrease in stroke volume, reflection coefficient, and cardiac output, as well as an increase in pulse pressure amplification and reflected intensity peak. Among initial PWF levels, only the excess pressure integral correlated with pre-dialysis FO; however, FO correlated positively with intradialytic changes in systolic and mean blood pressure, pulse wave velocity, and reservoir pressure, indicating attenuated decreases in these parameters when baseline fluid excess was higher.
Conclusion
In the studied cohort, RBV and cUFV showed distinct association profiles with PWFs during hemodialysis. These relationships warrant consideration in studies assessing or intervening on PWFs in dialysis patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- AIT Austrian Institute of Technology, Center for Health and Bioresources, Medical Signal Analysis, Vienna, Austria.
- Division of Nephrology and Dialysis, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
- Department of Epidemiology, Center for Public Health, Medical University of Vienna, Vienna, Austria.
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
- Division of Nephrology and Dialysis, Department of Medicine III, Medical University of Vienna, Vienna, Austria, manfred.hecking@meduniwien.ac.at.
- Department of Epidemiology, Center for Public Health, Medical University of Vienna, Vienna, Austria, manfred.hecking@meduniwien.ac.at.
Zitieren
APA
Krenn, S., Pstras, L., Mussnig, S., Kurnikowski, A., Wassertheurer, S., Hecking, M., & Mayer, C. C. (2026). Effects of Pre-Dialysis Fluid Overload, Intradialytic Relative Blood Volume Levels, and Cumulative Ultrafiltration Volume on Pulse Wave-Derived Features during Hemodialysis: Results from a Longitudinal Cohort Study. Kidney and Blood Pressure Research, 51(1), 378-393. https://doi.org/10.1159/000552495
Vancouver
Krenn S, Pstras L, Mussnig S, Kurnikowski A, Wassertheurer S, Hecking M, et al. Effects of Pre-Dialysis Fluid Overload, Intradialytic Relative Blood Volume Levels, and Cumulative Ultrafiltration Volume on Pulse Wave-Derived Features during Hemodialysis: Results from a Longitudinal Cohort Study. Kidney and Blood Pressure Research. 2026;51(1):378-393. doi:10.1159/000552495
BibTeX
@article{Krenn2026,
author = {Krenn, Simon and Pstras, Leszek and Mussnig, Sebastian and Kurnikowski, Amelie and Wassertheurer, Siegfried and Hecking, Manfred and Mayer, Christopher Clemens},
title = {Effects of Pre-Dialysis Fluid Overload, Intradialytic Relative Blood Volume Levels, and Cumulative Ultrafiltration Volume on Pulse Wave-Derived Features during Hemodialysis: Results from a Longitudinal Cohort Study},
journal = {Kidney and Blood Pressure Research},
year = {2026},
volume = {51},
number = {1},
pages = {378--393},
doi = {10.1159/000552495}
}
EUVIMED