Fachartikel in der Zeitschrift Ophthalmologica, online erschienen am 13.03.2026. Verfasst von Luke Michaels und 5 weiteren Autor:innen. Beteiligte Einrichtung: St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK, luke.michaels@kcl.ac.uk. Hauptthemen laut MEDLINE: Vitreoretinal Surgery, Intraocular Pressure, Sulfur Hexafluoride, Vitreous Body. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Concentration mix errors of fluorinated gases commonly used in vitreoretinal surgery can lead to catastrophic elevations in intraocular pressure (IOP). The timing and optimal management of this complication is poorly understood. This study aimed to evaluate the impact of controlled venting on IOP elevation following simulated gas mix errors.
Methods
A validated mass transfer model of intraocular gas dynamics was used to simulate the properties of “isovolumetric” gas concentrations of 20% SF6, 16% C2F6, and 12% C3F8, along with the most common concentration mix errors: double concentration, 10/3 (3.33×) concentration, and 100% gas. Simulations were performed on eyes with vitreous cavity volumes of 4.0 mL, 7.2 mL, and 10.0 mL (representing hyperopic to highly myopic eyes). The model calculated gas volume and IOP over time, both before and after controlled venting events to normalise IOP.
Results
All gas concentration errors produced complete gas fill and rapid IOP elevations. Only double concentration errors generated IOPs potentially manageable with medical therapy (peak 60 mm Hg for 40% SF6, 75 mm Hg for 32% C2F6, 61 mm Hg for 24% C3F8). Simulated 10/3 (3.33×) and 100% concentrations resulted in extreme IOP elevations incompatible with ocular perfusion. Controlled gas venting on day 1 normalised IOP for SF6 but repeated venting procedures were required for C2F6 and C3F8 due to continued gas re-expansion. Eyes with larger vitreous cavities experienced prolonged IOP elevation and delayed equilibration after venting.
Conclusion
Gas concentration mix errors produce rapid and often unsalvageable IOP rises. While limited SF6 over-concentrations may be temporarily stabilised with medical therapy and controlled venting, most scenarios, especially involving C2F6 or C3F8, require urgent surgical complete gas exchange.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK, luke.michaels@kcl.ac.uk.
- Faculty of Life Sciences and Medicine, Kings College London, London, UK, luke.michaels@kcl.ac.uk.
- Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy.
- Department of Bioengineering, Imperial College, London, UK.
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.
- Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Humanitas Research Hospital, Milan, Italy.
Zitieren
APA
Michaels, L., Ferrara, M., van Batenburg-Sherwood, J., Romano, M. R., Guillemaut, J. Y., & Williamson, T. H. (2026). Gas Concentration Errors in Vitreoretinal Surgery: Insights from a Model of Gas Mass Transfer Dynamics. Ophthalmologica, 1-9. https://doi.org/10.1159/000551468
Vancouver
Michaels L, Ferrara M, van Batenburg-Sherwood J, Romano MR, Guillemaut JY, Williamson TH. Gas Concentration Errors in Vitreoretinal Surgery: Insights from a Model of Gas Mass Transfer Dynamics. Ophthalmologica. 2026:1-9. doi:10.1159/000551468
BibTeX
@article{Michaels2026,
author = {Michaels, Luke and Ferrara, Mariantonia and van Batenburg-Sherwood, Joseph and Romano, Mario R and Guillemaut, Jean-Yves and Williamson, Tom H},
title = {Gas Concentration Errors in Vitreoretinal Surgery: Insights from a Model of Gas Mass Transfer Dynamics},
journal = {Ophthalmologica},
year = {2026},
pages = {1--9},
doi = {10.1159/000551468}
}
EUVIMED