Blunt Cardiovascular Response to Active Standing in Patients with Intracranial Atherosclerotic Stenosis
Cerebrovascular Diseases · 2025
DOI: 10.1159/000549825 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cerebrovascular Diseases, 2025. Verfasst von Yufan Cao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Chinese Academy of Medical Sciences and Peking Union Medical College Hospital/Peking Union Medical College, Beijing, China. Hauptthemen laut MEDLINE: Cerebrovascular Circulation, Heart Rate, Intracranial Arteriosclerosis, Standing Position. Die Arbeit nennt 38 Literaturangaben.
Abstract (Originalsprache)
Introduction
We sought to investigate the dynamic changes in cerebral blood flow (CBF) and heart rate (HR) and their interconnectivity in response to active standing, a physiological model to simulate rapid blood pressure fluctuation, in patients with intracranial atherosclerotic stenosis (ICAS).
Methods
The study was a cross-sectional analysis within a prospective cohort. Transcranial Doppler monitoring was performed in 302 middle cerebral arteries from 182 subjects. All subjects started in the supine position, followed by rapid standing. The CBF velocity and HR trend curves were recorded and compared between the groups.
Results
After the subject stood up, the CBF velocity curve showed a rapid decrease followed by a rebound, while the HR curve showed a rapid increase and dropped back to the baseline. The time to peak CBF velocity rebound was prolonged in the stenotic arteries (19.53 ± 3.8 s) compared with the normal arteries (17.09 ± 3.09 s) (p < 0.001). In patients with ICAS, the maximum HR rangeability was lower (18.1 ± 8.1 vs. 21.3 ± 7.1 bpm, p = 0.013) and the HR variability (HRV) had a trend lower (1.20 ± 0.134 vs. 1.24 ± 0.118, p = 0.07) than the normal controls. The mediating effect analysis showed that the HRV acted as a partial mediating factor of the stenosis on the prolongation of the time to peak CBF velocity rebound, and the proportion of the mediating effect was 12.76%.
Conclusions
The CBF in the intracranial stenotic artery has a blunt response to rapid blood pressure fluctuation, which could be partially mediated by the decrease in HRV, suggesting a new potential heart-brain talk. HR monitoring could be considered in the management of ICAS-related cerebral hypoperfusion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, Chinese Academy of Medical Sciences and Peking Union Medical College Hospital/Peking Union Medical College, Beijing, China.
- Research and development, Beijing Chioy MEDICAL Technology Co., Ltd, Beijing, China.
- Engineering and Scientific Computing Research Laboratory, Chinese Academy of Sciences Shenzhen Institute of Advanced Technology, Shenzhen, China.
- Department of Neurology, Chinese Academy of Medical Sciences and Peking Union Medical College Hospital/Peking Union Medical College, Beijing, China, qianmin@pumch.cn.
- Department of Neurology, Chinese Academy of Medical Sciences and Peking Union Medical College Hospital/Peking Union Medical College, Beijing, China, xuwhpumch@qq.com.
Zitieren
APA
Cao, Y., Dai, Y., Liu, J., Li, X., Gao, S., Liu, J., Li, S., Qian, M., & Xu, W. (2025). Blunt Cardiovascular Response to Active Standing in Patients with Intracranial Atherosclerotic Stenosis. Cerebrovascular Diseases. https://doi.org/10.1159/000549825
Vancouver
Cao Y, Dai Y, Liu J, Li X, Gao S, Liu J, et al. Blunt Cardiovascular Response to Active Standing in Patients with Intracranial Atherosclerotic Stenosis. Cerebrovascular Diseases. 2025. doi:10.1159/000549825
BibTeX
@article{Cao2025,
author = {Cao, Yufan and Dai, Yuexuan and Liu, Jiaxin and Li, Xin and Gao, Shan and Liu, Jia and Li, Shun and Qian, Min and Xu, Weihai},
title = {Blunt Cardiovascular Response to Active Standing in Patients with Intracranial Atherosclerotic Stenosis},
journal = {Cerebrovascular Diseases},
year = {2025},
doi = {10.1159/000549825}
}
EUVIMED