EUVIMEDEUVIMED entdecken
Crossref

MRI Lung Volume Prediction of ECMO and Mortality in Congenital Diaphragmatic Hernia

Amelia Gavulic, Madelyn Gerken, Philip Stanic, Todd M Jenkins, Monica Wagner, Stefanie Riddle, Laura Galganski, Beth Rymeski

Fetal Diagnosis and Therapy · 2025

DOI: 10.1159/000549792 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fetal Diagnosis and Therapy, 2025. Verfasst von Amelia Gavulic und 7 weiteren Autor:innen. Beteiligte Einrichtung: University of Cincinnati College of Medicine, Cincinnati, Ohio, USA. Hauptthemen laut MEDLINE: Hernias, Diaphragmatic, Congenital, Extracorporeal Membrane Oxygenation, Magnetic Resonance Imaging, Lung. Die Arbeit nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study evaluated fetal MRI lung measurements with ECMO use and survival of prenatally diagnosed CDH.

Methods

This was a retrospective chart review of 113 patients from January 2012 to December 2023 with prenatally diagnosed congenital diaphragmatic hernias. Lung measurements from prenatal MRIs, infant ECMO use, and survival were analyzed to determine optimal cut-off value for outcome prediction.

Results

Patients were categorized as mild (10.1%, n = 11), moderate (34.3%, n = 37), and severe (55.6%, n = 60). Mortality was 29.2% (n = 33), and 52.2% (n = 59) required ECMO. Patients undergoing FETO (n = 11) were excluded from statistical analysis. Median change in total lung volume, ipsilateral lung, and contralateral lung from early to late gestation MRI was 15.1 mL (IQR: 9.3–21.7), 1.5 mL (IQR: 0.1–3.1), and 13.4 mL (IQR: 8.1–18.34), respectively. Optimal cut-off values, sensitivity, specificity, positive predictive value, and negative predictive value were calculated for each volume parameter in terms of predicting ECMO use and mortality. Ipsilateral and contralateral lung growth below the cut-off significantly predicted ECMO use (p < 0.05). There was no significance for any cut-offs predicting mortality.

Conclusion

Lung volume growth measured by MRI in prenatally diagnosed CDH may be a useful predictor of ECMO use and mortality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hernias, Diaphragmatic, CongenitalExtracorporeal Membrane OxygenationMagnetic Resonance ImagingLungHumansFemaleRetrospective StudiesPregnancyLung Volume MeasurementsPrenatal DiagnosisInfant, NewbornMalePredictive Value of TestsAdult

Stichwörter der Autor:innen

Congenital diaphragmatic herniaECMOFetal MRIFetal lung volumes

Autor:innen und Institutionen

  • University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.
  • Division of Biostatistics and Epidemiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Division of Pediatric General and Thoracic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Division of Neonatology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Division of Pediatric General and Thoracic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA, beth.rymeski@cchmc.org.

Zitieren

APA

Gavulic, A., Gerken, M., Stanic, P., Jenkins, T. M., Wagner, M., Riddle, S., Galganski, L., & Rymeski, B. (2025). MRI Lung Volume Prediction of ECMO and Mortality in Congenital Diaphragmatic Hernia. Fetal Diagnosis and Therapy. https://doi.org/10.1159/000549792

Vancouver

Gavulic A, Gerken M, Stanic P, Jenkins TM, Wagner M, Riddle S, et al. MRI Lung Volume Prediction of ECMO and Mortality in Congenital Diaphragmatic Hernia. Fetal Diagnosis and Therapy. 2025. doi:10.1159/000549792

BibTeX
@article{Gavulic2025,
  author = {Gavulic, Amelia and Gerken, Madelyn and Stanic, Philip and Jenkins, Todd M and Wagner, Monica and Riddle, Stefanie and Galganski, Laura and Rymeski, Beth},
  title = {MRI Lung Volume Prediction of ECMO and Mortality in Congenital Diaphragmatic Hernia},
  journal = {Fetal Diagnosis and Therapy},
  year = {2025},
  doi = {10.1159/000549792}
}
Kostenlos starten →