EUVIMEDEUVIMED entdecken
Crossref

A Gelatine-Methylene Blue Method for Enhanced Visualization of Digital Artery Perforators in Cadaveric Studies

Rasyidah Rehir, Sameer Dhumale

Journal of Vascular Research · 2026

DOI: 10.1159/000549047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vascular Research, 2026. Verfasst von Rasyidah Rehir und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Old Medical School, Edinburgh, UK, rasyidahrehir@ukm.e…. Hauptthemen laut MEDLINE: Methylene Blue, Gelatin, Fingers, Ulnar Artery. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Precise visualization of digital artery perforators (DAPs) is essential for anatomical research and microsurgical planning. Traditional injection techniques often fail to highlight small calibre vessels and pose technical or environmental limitations. Gelatine is biocompatible and easy to use, and methylene blue provides strong contrast. However, no prior studies have combined both for vascular enhancement.

Methods

Twenty digits from five fresh frozen cadaveric upper limbs (mean age: 83 years, all female) were used. After saline irrigation, radial and ulnar arteries were perfused with 24 g/L gelatine and 1% w/v methylene blue via 18-G cannulas. Limbs were warmed to enhance dye flow, then chilled overnight. Digits were dissected to expose DAPs. Kruskal-Wallis tests confirmed consistent perfusion and high inter- and intra-observer reliability (p ≥ 0.81).

Conclusion

This gelatine-methylene blue technique provides a reliable, cost-effective method for clear and reproducible vascular visualization in cadaveric studies and surgical training.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Methylene BlueGelatinFingersUlnar ArteryRadial ArteryContrast MediaHumansFemaleAged, 80 and overCadaverReproducibility of ResultsAgedObserver Variation

Stichwörter der Autor:innen

Cadaveric dissectionDigital artery perforatorsGelatineMethylene blueVascular visualization

Substanzen

Methylene BlueGelatinContrast Media

Autor:innen und Institutionen

  • Department of Anatomy, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Old Medical School, Edinburgh, UK, rasyidahrehir@ukm.edu.my.
  • Department of Anatomy, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras, Malaysia, rasyidahrehir@ukm.edu.my.
  • Department of Anatomy, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Old Medical School, Edinburgh, UK.

Zitieren

APA

Rehir, R., & Dhumale, S. (2026). A Gelatine-Methylene Blue Method for Enhanced Visualization of Digital Artery Perforators in Cadaveric Studies. Journal of Vascular Research. https://doi.org/10.1159/000549047

Vancouver

Rehir R, Dhumale S. A Gelatine-Methylene Blue Method for Enhanced Visualization of Digital Artery Perforators in Cadaveric Studies. Journal of Vascular Research. 2026. doi:10.1159/000549047

BibTeX
@article{Rehir2026,
  author = {Rehir, Rasyidah and Dhumale, Sameer},
  title = {A Gelatine-Methylene Blue Method for Enhanced Visualization of Digital Artery Perforators in Cadaveric Studies},
  journal = {Journal of Vascular Research},
  year = {2026},
  doi = {10.1159/000549047}
}
Kostenlos starten →