Technological Influence on Retina Fellows’ Learning Curves: A Prospective Study of Digital versus Analog Microscopes (The BRAVE Study)
Ophthalmologica · 2025
DOI: 10.1159/000548785 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Ophthalmologica, 2025. Verfasst von Matias Iglicki und 5 weiteren Autor:innen. Beteiligte Einrichtung: Private Retina Office, University of Buenos Aires, Buenos Aires, Argentina, matiasiglicki@gmail.com. Hauptthemen laut MEDLINE: Learning Curve, Clinical Competence, Ophthalmology, Education, Medical, Graduate. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Introduction
The BRAVE Study (Bridging Retina Fellows’ Advancement with Visualization Enhancements) aims to compare the learning curves of retina fellows performing epiretinal membrane (ERM) surgery trained using digital heads-up display (HUD) systems versus analog surgical operating microscopes (SOMs) in a prospective manner. Fellows were assigned exclusively to either HUD or SOM for all ERM surgeries during the 2-year study. There was no crossover between modalities. Posterior vitreous detachment was consistently induced by active suction under the macula. Trypan blue was routinely applied to aid in visualization of the ILM/ERM. This standardized approach was used across both groups.
Methods
In this prospective 2-year study, four retina fellows were trained exclusively with either a digital (NGENUITY® 3D) or analog (ZEISS OPMI LUMERA 700) microscope. Each fellow performed 127 ERM surgeries (total: 508). Learning progression was rated using an 18-item Likert scale (1–5; higher scores = greater difficulty). Primary outcomes included visualization quality, surgical comfort, and instructor interaction. A linear regression model assessed learning trends.
Results
Fellows using the digital system achieved proficiency within 3 months, compared to 7 months for the analog group. Initial difficulty scores were significantly lower in the digital group (1.64 vs. 5.14, p < 0.001). Monthly improvement rates were −0.30 (digital) vs. −0.86 (analog). Instructor interventions were higher in the analog group during the first 6 months (p < 0.05) but equalized later. Early ergonomic and comfort advantages with digital systems also leveled over time.
Conclusions
Digital HUD systems enhance early skill acquisition and reduce learning-related challenges in retina fellow training. Although long-term proficiency equalizes, these systems offer clear early-phase benefits, supporting their integration into surgical education.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Private Retina Office, University of Buenos Aires, Buenos Aires, Argentina, matiasiglicki@gmail.com.
- Ophthalmology Division, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
- Gray Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
- Medical Investigation Institute "Alfredo Lanari", University of Buenos Aires, Buenos Aires, Argentina.
- Statistical Analysis Laboratory School of Psychology, University of Buenos Aires, Buenos Aires, Argentina.
- Instituto "Prof. Dr. Raúl Vaccarezza", University of Buenos Aires, Buenos Aires, Argentina.
Zitieren
APA
Iglicki, M., Zur, D., Khoury, M., Muiños, R., Melamud, J. I., & Loewenstein, A. (2025). Technological Influence on Retina Fellows’ Learning Curves: A Prospective Study of Digital versus Analog Microscopes (The BRAVE Study). Ophthalmologica. https://doi.org/10.1159/000548785
Vancouver
Iglicki M, Zur D, Khoury M, Muiños R, Melamud JI, Loewenstein A. Technological Influence on Retina Fellows’ Learning Curves: A Prospective Study of Digital versus Analog Microscopes (The BRAVE Study). Ophthalmologica. 2025. doi:10.1159/000548785
BibTeX
@article{Iglicki2025,
author = {Iglicki, Matias and Zur, Dinah and Khoury, Marina and Muiños, Roberto and Melamud, Javier Ignacio and Loewenstein, Anat},
title = {Technological Influence on Retina Fellows’ Learning Curves: A Prospective Study of Digital versus Analog Microscopes (The BRAVE Study)},
journal = {Ophthalmologica},
year = {2025},
doi = {10.1159/000548785}
}
EUVIMED