Influence of Different Parameters on the Labeling Efficiency of Technetium-99m Radiopharmaceuticals: Kuwait Nuclear Medicine Departments Experiences
Medical Principles and Practice · 2025
DOI: 10.1159/000548454 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Principles and Practice, 2025. Verfasst von Fatma J Al-Saeedi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, College of Medicine, Kuwait University, Jabriya, Kuwait, fatma.alsaeedi@ku.edu.kw. Hauptthemen laut MEDLINE: Radiopharmaceuticals, Technetium, Drug Labeling, Isotope Labeling. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objectives
The objective of this study was to evaluate the effects of temperature, light, pH, reducing agents, oxygen, dilution, syringe material, solvents, and operator differences on the labeling efficiency of 99mTc-radiopharmaceuticals.
Methods
Five GE Healthcare kits ([99mTc]Tc-HMPAO, [99mTc]Tc-MAA, [99mTc]Tc-DMSA, [99mTc]Tc-DTPA, and [99mTc]Tc-tin colloid) were reconstituted with 99mTc-pertechnetate in saline and tested under varying conditions.
Results
Labeling efficiency was largely unaffected, except for [99mTc]Tc-HMPAO, which showed significant reductions with temperature changes (p < 0.001). UV light significantly degraded labeling in all kits (p < 0.001), and pH changes reduced [99mTc]Tc-DMSA efficiency.
Conclusion
Stability depends on optimized formulation, storage, and preparation, and shelf-life extension may be feasible under controlled conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, College of Medicine, Kuwait University, Jabriya, Kuwait, fatma.alsaeedi@ku.edu.kw.
- Department of Nuclear Medicine, Mubarak Al-Kabeer Hospital, Ministry of Heath, Hawalli Health Area, Jabriya, Kuwait.
- Department of Nuclear Medicine, Head Radiopharmacy Unit, Kuwait Cancer Control Center, Ministry of Heath, Sabah Health Area, Shuwaikh, Kuwait.
Zitieren
APA
Al-Saeedi, F. J., Al-Qallaf, Z. S., Khalaf, S. N., Al-Farsi, S. K., & Al-Enizi, Z. Y. (2025). Influence of Different Parameters on the Labeling Efficiency of Technetium-99m Radiopharmaceuticals: Kuwait Nuclear Medicine Departments Experiences. Medical Principles and Practice. https://doi.org/10.1159/000548454
Vancouver
Al-Saeedi FJ, Al-Qallaf ZS, Khalaf SN, Al-Farsi SK, Al-Enizi ZY. Influence of Different Parameters on the Labeling Efficiency of Technetium-99m Radiopharmaceuticals: Kuwait Nuclear Medicine Departments Experiences. Medical Principles and Practice. 2025. doi:10.1159/000548454
BibTeX
@article{AlSaeedi2025,
author = {Al-Saeedi, Fatma J and Al-Qallaf, Zainab S and Khalaf, Shatha N and Al-Farsi, Shima Kh and Al-Enizi, Zakiyah Y},
title = {Influence of Different Parameters on the Labeling Efficiency of Technetium-99m Radiopharmaceuticals: Kuwait Nuclear Medicine Departments Experiences},
journal = {Medical Principles and Practice},
year = {2025},
doi = {10.1159/000548454}
}
EUVIMED