Rotational Stability of Three Toric Intraocular Lens Platforms in Patients Undergoing Repositioning Surgery
Ophthalmic Research · 2025
DOI: 10.1159/000547762 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Ophthalmic Research, 2025. Verfasst von Honglei Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China. Hauptthemen laut MEDLINE: Lenses, Intraocular, Lens Implantation, Intraocular, Visual Acuity, Phacoemulsification. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
This study evaluated the rotational stability of three toric intraocular lens (TIOL) platforms in patients undergoing repositioning surgery.
Methods
This comparative retrospective study enrolled eyes that underwent cataract surgery and implanted with an AcrySof, AT TORBI/LISA, or TECNIS TIOL. Patients who experienced TIOL misalignment ≥10° postoperatively and underwent repositioning surgery were included. The incidence of repositioning surgery after cataract surgery and the misalignment degree before and after repositioning surgery of the three TIOL platforms were mainly compared.
Results
Of the 2,598 eyes implanted with TIOLs, 56 eyes (2.156%) underwent repositioning. The repositioning rates for the AcrySof, AT TORBI/LISA, and TECNIS platforms were 0.848% (10/1,179), 2.935% (28/954), and 3.871% (18/465), respectively, showing significant differences (p < 0.001). Misalignment degrees before repositioning surgery for the AcrySof, AT TORBI/LISA, and TECNIS TIOLs were 27.90 ± 15.74°, 60.79 ± 18.79°, and 31.61 ± 20.84°, respectively (p < 0.001). AT TORBI/LISA platform had a significantly greater misalignment degree compared to AcrySof (difference: 32.89°, p < 0.001) and TECNIS platforms (difference: 29.18°, p < 0.001). There was no significant difference between AcrySof and TECNIS (difference: 3.71°, p = 0.629). After repositioning, the AT TORBI/LISA platform showed significantly higher misalignment degrees compared to AcrySof and TECNIS (difference: 6.63°; 5.49°, p = 0.009).
Conclusion
AcrySof TIOLs had a lower incidence of repositioning surgery compared with AT TORBI/LISA and TECNIS, while AT TORBI/LISA TIOLs exhibited a higher degree of axis misalignment both before and after repositioning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China.
- State Key Laboratory Cultivation Base, Shandong Key Laboratory of Eye Diseases, Qingdao, China.
- School of Ophthalmology, Shandong First Medical University, Jinan, China.
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China, wuxiaominglmm@126.com.
- State Key Laboratory Cultivation Base, Shandong Key Laboratory of Eye Diseases, Qingdao, China, wuxiaominglmm@126.com.
- School of Ophthalmology, Shandong First Medical University, Jinan, China, wuxiaominglmm@126.com.
Zitieren
APA
Li, H., Liu, D., Sun, J., Zhang, J., Teng, Y., Gao, J., & Wu, X. (2025). Rotational Stability of Three Toric Intraocular Lens Platforms in Patients Undergoing Repositioning Surgery. Ophthalmic Research. https://doi.org/10.1159/000547762
Vancouver
Li H, Liu D, Sun J, Zhang J, Teng Y, Gao J, et al. Rotational Stability of Three Toric Intraocular Lens Platforms in Patients Undergoing Repositioning Surgery. Ophthalmic Research. 2025. doi:10.1159/000547762
BibTeX
@article{Li2025,
author = {Li, Honglei and Liu, Dongle and Sun, Jiajun and Zhang, Jingwen and Teng, Yingli and Gao, Jing and Wu, Xiaoming},
title = {Rotational Stability of Three Toric Intraocular Lens Platforms in Patients Undergoing Repositioning Surgery},
journal = {Ophthalmic Research},
year = {2025},
doi = {10.1159/000547762}
}