Influence of Different Hemodialysis Biocontrols on the Achievement of the Convective Volume
Blood Purification · 2025
DOI: 10.1159/000546642 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Blood Purification, 2025. Verfasst von Patricia Muñoz Ramos und 13 weiteren Autor:innen. Beteiligte Einrichtung: Nephrology Department, Hospital Universitario Infanta Leonor, Madrid, Spain. Hauptthemen laut MEDLINE: Hemodiafiltration, Renal Dialysis, Kidney Failure, Chronic. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Post-dilution on-line hemodiafiltration (OL-HDF) has been shown to reduce all-cause mortality in hemodialysis (HD) patients when high substitution volumes are achieved. To date, little emphasis has been placed on the impact of different biocontrols in achieving high replacement volumes. The aim of the present study was to compare the substitution volume achieved with three different monitors using the three available automatic systems.
Methods
Prospective, observational cross-over study of prevalent patients on post-dilution OL-HDF. Each patient underwent 9 consecutive post-dilution OL-HDF sessions with each of the monitors included in the study: Artis, 6008, and Surdial X with the corresponding biocontrols: UltraControl, AutoSub+, and Max-Sub, respectively. After each session, the final convective volume and other parameters related to HD and medium-molecule clearance were collected.
Results
Thirteen patients were included (57% male, age 62 ± 14 years), of whom 71% were dialyzed via an arteriovenous fistula. The mean time on dialysis was 51 ± 32 months. Convective volume achieved with Max-Sub biocontrol (Surdial X monitor) was higher than that achieved with UltraControl biocontrol (Artis monitor) (31 ± 2 vs. 29.4 ± 2.2 L/session, p = 0.009) and AutoSub+ biocontrol (6008 monitor) (31 ± 2 vs. 28.9 ± 2.6 L/session, p = 0.01). On multivariate analysis, factors associated with higher convective volume were the prescription of Max-Sub biocontrol (B 1.61, 95% CI [0.41–2.80], p = 0.009), TPM (B 0.02, 95% CI [0.01–0.03], p = 0.018), blood processed (B 0.17, 95% CI [0.08–0.26], p < 0.001), and not having diabetes mellitus (B −1.66, 95% CI [−2.72 to 0.59], p = 0.002).
Conclusion
The volume achieved by convective transport can vary according to the type of biocontrol, with Max-Sub performing the best out of the 3 biocontrol systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Nephrology Department, Hospital Universitario Infanta Leonor, Madrid, Spain.
- Nephrology Department, Hospital Universitario de La Princesa, Madrid, Spain.
- RICORS2040, Madrid, Spain.
- Department of Medicine, Universidad Complutense de Madrid, Madrid, Spain.
Zitieren
APA
Muñoz Ramos, P., Guasch, L., Conejo, D., Rodríguez, E., López, V., Quiroga, B., Lucena, R., Puerta, M., Ortega, M., Medina, L., Procaccini, F. L., Martín-Navarro, J., Alcázar, R., & de Sequera, P. (2025). Influence of Different Hemodialysis Biocontrols on the Achievement of the Convective Volume. Blood Purification. https://doi.org/10.1159/000546642
Vancouver
Muñoz Ramos P, Guasch L, Conejo D, Rodríguez E, López V, Quiroga B, et al. Influence of Different Hemodialysis Biocontrols on the Achievement of the Convective Volume. Blood Purification. 2025. doi:10.1159/000546642
BibTeX
@article{MuozRamos2025,
author = {Muñoz Ramos, Patricia and Guasch, Laura and Conejo, David and Rodríguez, Esther and López, Virginia and Quiroga, Borja and Lucena, Rafael and Puerta, Marta and Ortega, Mayra and Medina, Laura and Procaccini, Fabio Luca and Martín-Navarro, Juan and Alcázar, Roberto and de Sequera, Patricia},
title = {Influence of Different Hemodialysis Biocontrols on the Achievement of the Convective Volume},
journal = {Blood Purification},
year = {2025},
doi = {10.1159/000546642}
}
EUVIMED